![background image](http://html.mh-extra.com/html/iai/mcon-c/mcon-c_instruction-manual_603985307.webp)
297
[19] Default movement direction for excitation-phase signal
detecting movement (Parameter No.28)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
28 Default Movement Direction for
Excitation-phase Signal Detection PHSP
–
0 : Reversed
direction
1 : Forward
direction
In accordance
with actuator
Excitation detection
(Note)
starts when the servo is turned ON for the first time after the power is
supplied. Define the detection direction at this time.
Even though it is generally unnecessary to change this setting, set this to the direction which
the motor is easy to move when the actuator interferes with the mechanical end or peripheral
object at the time the power is supplied.
If the direction not interfering is the same direction as the home return direction, set the same
values as set to Parameter No.5 Home Return Direction. If the direction is opposite, set the
other values from Parameter No.5. (If No.5 is 0, set 1. If No.5 is 1, set 0.)
Note 1 For Simple Absolute Type, the excitation detection is performed at the end of home
return operation.
[20] Excitation-phase signal detection time (Parameter No.29)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
Specifications
1 to 999
10
Pulse motor
type
29 Excitation-phase Signal
Detection Time
PHSP
msec
50 to 999
128
Servo motor
type
Excitation detection
(Note)
starts when the servo is turned ON for the first time after the power is
supplied. Define the detection direction at this time.
Even though it is generally unnecessary to change this setting, changing the setting of this
parameter may be effective when excitation error is generated or abnormal operation is
confirmed.
Please contact us in the case a change is necessary to this parameter.
Note 1 For Simple Absolute Type, the excitation detection is performed at the end of home
return operation.
For servo motor type and
pulse motor type only
For servo motor type and
pulse motor type only
Chapter 8 Parameter
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......