86
y
MCON Output → PLC Input (n is PLC input top word address from MCON)
(Note 1)
PLC
Input Area
Simple
Direct
Mode
Positioner 1
Mode
Direct
Indication
Mode
Positioner 2
Mode
Positioner 3
Mode
Positioner 5
Mode
Remote I/O
Mode
Details
n
Gateway Status 0
n+1
Gateway Status 1
3.4.3
n+2
Response Command
n+3
Data 0
n+4
Data 1
n+5
Data 2
n+6
Data 3
MCON
G
ate
way
Response
Area
n+7
Occupied Area
(Note 2)
3.4.11
n+8
Completed
Position No./
Simple
Alarm ID
(Axis No.0)
Status
Signal/
Completed
Position
(Axis No.0)
Completed
Position No./
Simple
Alarm ID
(Axis No.0)
Assignment
Area for
Axis No.0
n+9
Current Position
(Axis No.0)
Current
Position
(Axis No.0)
Status
Signal
(Axis No.0)
Assignment
Area for
Axis No.1
Status
Signal
(Axis No.0)
Assignment
Area for
Axis No.1
n+10
Completed Position No./
Simple Alarm ID
(Axis No.0)
Assignment
Area for
Axis No.2
Assignment
Area for
Axis No.2
n+11
Status Signal
(Axis No.0)
Command
Current
(Axis No.0)
Assignment
Area for
Axis No.1
Assignment
Area for
Axis No.3
Assignment
Area for
Axis No.1
Assignment
Area for
Axis No.3
n+12
Current
Speed
(Axis No.0)
Assignment
Area for
Axis No.4
Assignment
Area for
Axis No.4
n+13
Occupied
Area
(axis No.0)
Assignment
Area for
Axis No.5
Assignment
Area for
Axis No.5
n+14
Alarm Code
(Axis No.0)
Assignment
Area for
Axis No.6
Assignment
Area for
Axis No.6
n+15
Assignment
Area for
Axis No.1
Status
Signal
(Axis No.0)
Assignment
Area for
Axis No.7
Assignment
Area for
Axis No.7
n+16
to
n+23
Assignment
Area for
Axis No.1
Connected
Axes Response
Area
n+24
to
n+71
Assignment
Area for
Axis No.2
Assignment
Area for
Axis No.2
and later
Assignment
Area for
Axis No.2
and later
Assignment
Area for
Axis No.2
and later
3.4.4
to
3.4.10
Note 1 For CC-Link and CC-Link IE Field, from n to n+7 should be the bit address for
MCON output and n+8 should be the top address of the data register.
Note 2 This is the domain occupied unconditionally. Therefore, this domain cannot be used
for any other purpose.
◎
In the case of CC-Link
Station Type: Ver.2.00 Remote device station
Extended Cyclic Setting/Occupied Station Number Setting:
Register the information of the occupations displayed on Gateway Parameter Setting Tool to
the master unit. Connection cannot be established if information other than occupation is
set. [3.2.1 Operation Mode Setting]
Caution:
●
Remote I/O Mode cannot be used together with other modes.
●
Only Positioner 3 Mode and Remote I/O Mode are available to be selected in
CompoNet. (CompoNet occupies 32 bytes no matter of the number of axes.)
3.4 Fieldbus
Type
Address Map
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......