172
(2) Position zone signal (PZONE)
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Gain
set
Stop
mode
0
1
0.00
250.00
0.20
0.20
0
0
0.10
50.00
30.00
0
0
0
0
2
100.00
250.00
0.20
0.20
0
0
0.10
70.00
60.00
0
0
0
0
3
50.00
250.00
0.20
0.20
50
0
20.00
60.00
65.00
0
0
0
0
Set the zone range to the position table.
This set value becomes valid while the position number set in the zone range is executed. It
is kept effective also during the emergency stop unless the actuator is operated or the
memory of the origin is lost due to alarm.
(3) Output Ranges of Set Values and Signals
The zone output range differs depending on the difference of the values set in the zone
positive side and negative side.
1) Value set for positive side > value set for negative side:
Output signal turn ON in the range from the value on negative side to that on positive
side, and turns OFF out of the range
2) Value set for positive side < value set for negative side:
Output signal turn OFF in the range from the value on positive side to that on negative
side, and turns ON out of the range
[Example of Line Axis]
[Example of rotary actuator of multi-rotation specification in index mode]
Caution: Since this signal becomes effective after the coordinate system is established
after the home return is completed, it would not be output just with the power
turned ON.
Current
Position
Zone Signal Output
Zone Signal Output
0mm
30mm
70mm
100mm
ON
ON
ON
Set Value
Zone s : 70mm
Zone setting - : 30mm
Set Value
Zone s : 30mm
Zone setting - : 70mm
0
°
315
°
70
°
0
°
Set Value
Zone s : 70
°
Zone setting - : 315
°
315
°
70
°
Set Value
Zone s : 315
°
Zone setting - : 70
°
Setting of zone range
3.7 Control and Functions of Input and Output Signals of Modes Other than Remote I/O Mode
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......