15
8) Fan Unit
This is the fan unit to cool down the controller. This unit can be detached from the controller
for maintenance by removing the screw on the hook in the front of the controller.
9) Operation Mode Setting Switch
This is a switch to change the operation mode between Automatic Operation (AUTO) and
Manual Operation (MANU). The operation modes are provided to avoid the duplication of the
SIO (Serial) communication operation using PC software or a teaching pendant (described
as teaching tool from now on) and the operation with Fieldbus or PIO (Parallel I/O)
For the details of the mode selection, refer to 11) System I/O Connector.
10) SIO Connector
This is a connector dedicated for the teaching tool connection. [Refer to 2.3.7]
11) System I/O Connector
This is a connector for additional devices for the input of all-axes external emergency stop,
AUTO/MANU switchover and external regenerative resistor.
[Refer to 2.3.2]
It is connected in a series with the operation mode setting switch (AUTO/MANU) on the
front panel. The controller can be in the following modes by the mode selection on each
switch and teaching tool.
Condition
MCON status
Switch on Front Panel
Teaching Tool
Note 1
Operation Mode
Switchover Input
Note 2
AUTO
Prohibit PIO Startup
OFF (Input 0V)
AUTO
Accept PIO Startup
OFF (Input 0V)
AUTO
Accept PIO Startup
ON (Release)
MANU
Accept PIO Startup
ON (Release)
AUTO
MANU
Accept PIO Startup
OFF (Input 0V)
AUTO
Prohibit PIO Startup
ON (Release)
MANU
Prohibit PIO Startup
ON (Release)
MANU
MANU
Prohibit PIO Startup
OFF (Input 0V)
Note 1 : “Accept PIO Startup” and “Prohibit PIO Startup” are the functions to select the operation
mode of when the teaching tool is connected.
Note 2 : Refer to “2.2 [4] Layout for Mode Switchover Circuit” for the details.
Caution : (1) If “Accept PIO Startup” is selected on the teaching tool, the AUTO operation
becomes available no matter the condition of the front panel or external
switchover signal input, thus attention may have to be paid. In such a
condition, the actuator may get activated by following the signal from the host.
(2) The information of “Accept PIO Startup” or “Prohibit PIO Startup” is remained
when the teaching tool is removed from the controller. Do not fail to select
“Prohibit PIO Startup” when removing the teaching tool after finishing the
teaching operation or debugging.
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......