187
[3] Home return (HOME, HEND, PEND, MOVE)
Input
Output
PIO Signal
HOME
HEND
PEND
MOVE
Patterns 0 and 1
{
{
{
{
Patterns 2 and 4
{
{
{
×
Pattern 5
×
(Note1)
{
×
×
{
: Available,
×
: Unavailable
Note1 Pattern 5 cannot make a home return with HOME signal. Refer to 3.8.4 [1] Home
Return (ST0, HEND) for how to perform a home-return operation.
The HOME signal is intended for automatic home return. The HOME signal is caught at the
rising edge (ON edge) to start the home return. At completion of the home return, home
return completion signal HEND is turned ON. The home-return complete signal HEND is
kept ON unless the memory of origin point is lost for a reason. The positioning complete
signal PEND turns OFF and the moving signal MOVE turns ON during a home-return
operation.
Home Return Signal
HOME
(PLC→MCON)
Homing Completion Signal
HEND
(MCON→PLC)
Positioning Completion Signal
PEND
(MCON→PLC)
Moving Signal
MOVE
(MCON→PLC)
3.8 Control and functions of Input and output signals of Remote I/O Mode
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......