6.2 Selecting Automatic Current Reduction Feature
When performing a complete stop in the positioning, the current flows in constant amount
(Note 1)
regardless of the size of the external force in a normal condition (without using the automatic
current reduction feature). Using the automatic current reduction feature enables to flow the
current considering the influence of the external force, that will be able to save the power
consumption when the transported load is small.
Note 1 Parameter No. 12 “Current Limit Value at Positioning Stop”
To enabled / disabled the automatic current reduction feature can be set in Parameter No. 182.
Parameter
No.
Name
Unit
Input range
Initial
value
182
Auto Current Adj. Select
-
0: Disabled
1: Enabled
0
Shown below is a graph (example) of the current flow volume and velocity command in the
positioning operation in comparison of when the automatic current reduction feature is inactive
and when it is active.
•
The automatic current reduction feature: Disabled
•
The automatic current reduction feature: Enabled
Time
Current/
Ve
locity
Current Flow Volume
Velocity Command
Current Limit Value at
Positioning Stop
Time
Current/
Ve
locity
Current Flow Volume
Velocity Command
Current flow volume at stop considering external
force influence
Feature dedicated for pulse motor type
Chapter 6 Power-saving Function
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......