91
2) CC-Link and CC-Link IE Field
[Combination Example 1] When number of Simple Direct Mode/Positioner 1 Mode axes is
8 and number of Direct Indication Mode 0
CC-Link: (Extended Cyclic Setting/Number of Occupied
Stations: 4 times/2 stations)
PLC → MCON
MCON → PLC
Address
Description
Address
Description
RY 00 to 1F
Gateway Control
RX 00 to 1F
Gateway Status
RY 20 to 6F
Demand Command
RX 20 to 6F
Response Command
RY 70 to 7F
Cannot be used.
RX 70 to 7F
Cannot be used.
RY 80 to BF
Cannot be used.
RX 80 to BF
Cannot be used.
RWw 00 to 03
Axis No.0 Control
Information
RWr 00 to 03
Axis No.0 Status
Information
RWw 04 to 07
Axis No.1 Control
Information
RWr 04 to 07
Axis No.1 Status
Information
RWw 08 to 0B
Axis No.2 Control
Information
RWr 08 to 0B
Axis No.2 Status
Information
RWw 0C to 0F
Axis No.3 Control
Information
RWr 0C to 0F
Axis No.3 Status
Information
RWw 10 to 13
Axis No.4 Control
Information
RWr 10 to 13
Axis No.4 Status
Information
RWw 14 to 17
Axis No.5 Control
Information
RWr 14 to 17
Axis No.5 Status
Information
RWw 18 to 1B
Axis No.6 Control
Information
RWr 18 to 1B
Axis No.6 Status
Information
RWw 1C to 1F
Axis No.7 Control
Information
RWr 1C to 1F
Axis No.7 Status
Information
* There is no domain prepared in CC-Link IE Field for the line shaded in
.
3.4 Fieldbus
Type
Address Map
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......