356
3) In case of category 3 or 4
Connection Cable CB-CON-LB***
Controller
MCON-CG
ENBOUT
ENBIN
ENB2+
ENB2-
ENB1+
ENB1-
EMGOUT
EMGIN
EMG2+
EMG2-
EMG1+
EMG1-
RCB-LB-TGS
12
11
10
9
8
7
6
5
4
3
2
1
Solenoid Contactor Solenoid Contactor
Enable SW
Reset SW
Emergency Stop SW
Emergency Stop SW
For Category 4, insert
Reset Switch as shown
in the diagram.
For Category 3, layout
the wiring without
inserting Reset Switch.
For Category 4, make
the connection of A
and B open.
For category 3, make
a short circuit
between A and B.
EMG
-
S2
S1
24V
System I/O
Connector
Motor
Power
Supply
MP+24V
0V
24V
Power
Supply
Connector
TB-01D/TB-01DR or TB-02D
(or Dummy plug : DP-4S)
Chapter 10
Appendix
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......