25. Digital Storage Display Adjustments
25. Digital Storage
Display
Adjustments
Reference
Description
Equipment
Procedure
Preliminary Graticule
Adjustments
1 Trigger
Intensity Control
Line Generator
First, preliminary CRT graticule adjustments are performed to position
the graticule on the CRT. These preliminary adjustments assume that
repair has been performed on the associated circuitry. If no repair
has been performed on the assemblies listed under REFERENCE, the
preliminary adjustments are not necessary.
Next, the Sample and Hold Balance adjustments are performed. The
horizontal and vertical Offset and Gain adjustments are performed,
then the final CRT graticule adjustments are performed.
Last, the CRT annotation adjustments are performed to place the CRT
annotation in proper location with respect to the CRT graticule.
DIGITAL VOLTMETER
Figure 3-89. Digital Storage Display Adjustments Setup
Digital Voltmeter (DVM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP
Digitizing Oscilloscope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP
1. Place instrument upright as shown in Figure 3-89 with top and
Digital Storage cover removed.
2. Set LINE switch to ON and press
PRESET
]
3. Press TRACE A
4. Adjust
X GAIN and
Y GAIN to place graticule
information completely on CRT. See Figure 3-90 for location of
adjustment.
Adjustments 3-145
Summary of Contents for 8568B
Page 13: ...6 7 IF Section Bottom View 6 10 Contents 7 ...
Page 19: ......
Page 37: ......
Page 42: ......
Page 48: ......
Page 53: ......
Page 61: ......
Page 90: ......
Page 106: ...Test 13 Average Noise Level Test 2 84 Performance Tests ...
Page 162: ......
Page 224: ......
Page 268: ......
Page 270: ......
Page 272: ......
Page 278: ......
Page 312: ...AlVl Figure 6 6 IF Section Front View w3 w9 Major Assembly and Component locations 6 9 ...