16. Second IF Amplifier and Third Converter Adjustment
14.
15.
16.
17.
See Figure 3-65 for the typical response when the
filter
is properly adjusted.
On the scalar network analyzer, press
MAX. Press cursor
A, ON and set the cursor to the -3
point on the low side of the
filter response
Press cursor A and set the cursor to the -3
point on
the
high
side on
the
filter response. The cursor A should read 0 fO.l
I F A M P L I F I E R
C O N V E R T E R
\
A M P T D
Figure 3-64.
Location of 301.4
BPF and 280 MHz AMPTD Adjustments
Figure 3-65.
301.4 MHz
Filter Adjustment Waveform
On the synthesized sweeper, press
and set the Marker to the
-3
point on the low side of the filter response.
On the synthesized sweeper, press
and set the Marker to the
-3
point on the high side of the filter response.
3-114 Adjustments