Installation manual.
CNC 8060
CNC 8065
2.
MACHINE PA
RAMETERS.
Machin
e
parame
ters
for the
axe
s
an
d
spind
les.
·188·
(R
EF
: 1709)
2.5.26
Filters to eliminate resonance frequency.
FILTER
Filter table.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
This parameter shows the tables to configure the frequency filters. Up to 3 different filters
may be defined for each axis or spindle, hence being possible to eliminate several resonance
frequencies.
Frequency filters may be applied to axes and spindles. The filters defined for the spindle will
only be applied when it works as a C axis or it is doing a rigid tapping.
The CNC offers several filters. The "anti-resonance" filter (notch filter) that limits a zone of
the passing band and the low-pass filters that eliminate the banding passing from a particular
frequency on.
One of them is usually used, although both types of filters can also be applied to the same
axis or spindle when the resonance frequency is within the bandwidth of a "low passing" filter.
In order to obtain a good part finish, it is recommended to set all the axes that interpolate
with each other with the same filter type and with the same frequency.
FILTER n
Filter configuration.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Each table has the following machine parameters to configure it.
ORDER
Filter order.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: From 0 to 10 for low passing filter / from 0 to 5 for anti-resonance filter / from 0 to 50
for FAGOR low passing filter.
Default value: 0 (No filter is applied).
Associated variable: (V.)[ch].MPA.ORDER[nb].xn
Parameter included in the FILTER table.
The down ramp is dampened down; the higher the order the greater the drop. A higher order
implies more calculation; therefore, we recommend to consult our Technical support
department before modifying this parameter.
TYPE
Filter type.
Parameter valid for linear and rotary axes and spindles.
Parameter valid for analog drive, Sercos and simulated.
Possible values: Low Passing / Anti-resonance (notch filter) / Low passing FAGOR.
Default value: Low Passing.
Associated variable: (V.)[ch].MPA.TYPE[nb].xn
Parameter included in the FILTER table.
Usually, rigid and robust machines have a passing band of up to 30 Hz; i.e. they are capable
of responding up to this frequency. The rest of the machines may have resonance at lower
frequencies (10 Hz or less) that are generated on usual paths.
FILTER
ORDER
Filter order.
TYPE
Filter type.
FREQUENCY
Cut-off or center frequency.
NORBWIDTH
Normal bandwidth.
SHARE
Percentage of signal going through the filter.
Summary of Contents for CNC 8060
Page 1: ...Ref 1709 8060 8065 CNC Installation manual...
Page 10: ...BLANK PAGE 10...
Page 14: ...BLANK PAGE 14...
Page 20: ...BLANK PAGE 20...
Page 32: ...BLANK PAGE 32...
Page 36: ...BLANK PAGE 36...
Page 38: ...BLANK PAGE 38...
Page 40: ...BLANK PAGE 40...
Page 41: ...PART 1 INSTALLATION MANUAL...
Page 42: ...BLANK PAGE 42...
Page 532: ...Installation manual CNC 8060 CNC 8065 9 CNC VARIABLES 532 REF 1709...
Page 533: ...PART 2 CONCEPTS...
Page 534: ...BLANK PAGE 534...
Page 548: ...Installation manual CNC 8060 CNC 8065 10 GENERAL SETUP Configuration examples 548 REF 1709...
Page 644: ...Installation manual CNC 8060 CNC 8065 14 SUBROUTINES Assistance for subroutines 644 REF 1709...
Page 668: ...Installation manual CNC 8060 CNC 8065 15 HARDWARE Configure the PT100 inputs 668 REF 1709...
Page 697: ...Installation manual CNC 8060 CNC 8065 697 User notes REF 1709...