background image

 

FENCE ENERGIZER

M6000i / M12000i

Instructions

Instrucciones

-  ENG                      
-   ESP

Summary of Contents for G30813

Page 1: ...FENCE ENERGIZER M6000i M12000i Instructions Instrucciones ENG ESP...

Page 2: ...AIMER Whilst every effort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions...

Page 3: ...nergizer Controller 13 Accessories 19 Troubleshooting 20 Waste Electrical And Electronic Equipment 20 Espa ol Informaci n Importante 21 C mo funciona el energizador 24 Gu a de instalaci n 25 Entienda...

Page 4: ......

Page 5: ...a Residual Current Device RCD then a plug in RCD should always be used Ensure the Energizer is fully protected from rain condensation and other sources of moisture Ensure the Energizer has adequate ve...

Page 6: ...e of the orthogonal projection of the outermost conductors of the power line on the ground surface for a distance of 2 m for power lines operating at a nominal voltage not exceeding 1 000 V 15 m for p...

Page 7: ...t in which the extracts and contents are reproduced by the author nor is IEC in any way responsible for the other content or accuracy therein SERVICE OF DOUBLE INSULATED APPLIANCES In a double insulat...

Page 8: ...ct the fence It may take several days to train the animal and the fence may require minor adjustments Animals that are prone to jumping may be difficult to confine You may need to try different fence...

Page 9: ...rovided into the wall through the mounting holes in each corner Place the black bezel on the controller d Route the controller cable to the energizer and plug it into the data connector on the back co...

Page 10: ...f the cable wire and connect to the green terminal on the energizer 2 Attach the cable to the earth system by removing 10cm 4 of insulation from the cable at each Earth Stake G879 and then clamp the e...

Page 11: ...nd of the cable to the fence using a Joint Clamp G603 For instructions on fence installation see the Gallagher Power Fence Manual or go to www gallagher com Step 4 Turn the Energizer On a Plug the ene...

Page 12: ...fence fault Solid red when there is a sudden increase in fence load Wire to Energizer Controller The connector for the energizer controller is on the back cover This is also the connector for the opt...

Page 13: ...erformance Quickscan Bargraph Gives fast visual indication of fence voltage Zone Indication Arrow Highlights which energizer earth fence zone is being shown on the main display Status LED Green The en...

Page 14: ...p to 6 Fence Monitors or Alarm Systems See Accessories p 19 Navigation Buttons The navigation buttons allow you to view the performance of different areas of your fence system By pressing or you can s...

Page 15: ...e and the energizer output voltage is 7 3KV in this case The quickscan bargraph display is also indicating an output voltage of over 7KV Controller showing the energizer operating normally Voltage Ala...

Page 16: ...ors If the current goes above the alarm level you have set then the Energizer icon will flash and the status LED will flash red Controller showing the energizer in current alarm Status LED flashes red...

Page 17: ...on and wait 30 seconds Check the earth system voltage using the navigation keys The earth voltage should be 0 2 0 3KV or less If it is higher add earth stakes until 0 2 0 3KV is achieved In dry condit...

Page 18: ...usting Turning Off Alarms section p 16 Low Battery When viewing a zone if the battery icon is displayed then the zone device needs a battery replacement Controller showing the output voltage being adj...

Page 19: ...the fence at the fault location can be turned off and on using the Remote allowing a safe and convenient repair Gallagher Alarm System G57900 Create a security zone for your property by adding an Ala...

Page 20: ...any excess grass growth or short circuits on the fence Earth voltage is too high Earth system is inadequate Check connections to the earth system Add extra earth stakes No output and display shows Ene...

Page 21: ...ncendios No lo monte en lugares expuestos a las inclemencias del tiempo p e una pared donde le de excesivamente el sol Las reparaciones se deben realizar por un Servicio Autorizado de Gallagher No con...

Page 22: ...1000 e inferior o igual a 33000 4 Mayor de 33 000 5 Si los conectores y los cables de la cerca el ctrica son instalados pr ximos a una l nea de alta tensi n su altura por encima del suelo no debe supe...

Page 23: ...Puede encontrar m s informaci n sobre la IEC en ww eic ch La EIC no es responsable del lugar y contexto en el que dichos extractos y contenidos son reproducidos por el autor as como tampoco es respon...

Page 24: ...odr an causar un cortocircuito Utilice abrazaderas de uni n en todas las conexiones para asegurar un circuito de alta calidad Este energizador se debe conectar a tierra utilizando picas de tierra de m...

Page 25: ...ntrolador d Lleve el cable del controlador hasta el Energizador y ench felo en el conector de datos en la tapa trasera Paso 1 Monte el energizador Montar el Energizador en una pared bajo techo fuera d...

Page 26: ...conectar al terminal verde del Energizador 2 Acoplar el cable al sistema de tierra sacando 10cm 4 aislante del cable en cada varilla G8790 y agarrar el cable junto a cada varilla utilizando una abraz...

Page 27: ...nta del cable a la cerca con una abrazadera de l nea G6030 Para instrucciones para la instalaci n de la cerca vea el Manual del Gallagher Power FenceTM o vaya a www gallagher com Paso 4 Encender el En...

Page 28: ...Rojo fijo cuando hay un aumento repentino de la carga en la cerca Cable al controlador del energizador El conector del controlador del Energizador est en la tapa trasera Este tambi n es el conector pa...

Page 29: ...de la cerca Gr fico de barras de escaneo r pido Proporciona una indicaci n visual r pida del voltaje de la cerca Flecha de indicaci n de zona Se ala que zona se muestra en la pantalla LED de estado V...

Page 30: ...n de hasta 6 monitores de cerca o sistemas de alarma Vea los Accesorios p 102 Botones de navegaci n Los botones de navegaci n le permiten ver el funcionamiento de las diferentes reas de sus cerca Pul...

Page 31: ...salida del Energizador es de 7 3 KV en este caso El gr fico de barras de escaneo r pido tambi n indica un voltaje de salida por encima de 7KV Alarma de Voltaje Si el voltaje de salida del Energizador...

Page 32: ...ecida por defecto con la corriente desactivada y voltaje a 3 0 KV Alarma de Corriente Por defecto la alarma viene de f brica desactivada lo que se muestra Para mejorar su habilidad para encontrar fall...

Page 33: ...rra utilizando las teclas de navegaci n El voltaje de tierra deber a ser de 0 2 0 3 KV o inferior Si es superior a ada picas de tierra hasta conseguir de 0 2 a 0 3 KV En condiciones de suelos secos o...

Page 34: ...zona de la cerca vea la secci n Ajustar Apagar las alarmas p 99 Bater a baja Cuando se est visualizando una zona si el icono de la bater a se muestra en pantalla significa que el dispositivo que esta...

Page 35: ...ndida utilizando el control remoto permitiendo de esta manera una reparaci n segura Sistema de Alarma Gallagher G57900 Cree una zona de seguridad en su propiedad a adiendo un sistema de alarma que inc...

Page 36: ...energizador est bajo Hay un fallo en la cerca Quite el exceso de hierba o cortocircuitos en su cerca El voltaje de tierra es demasiado algo El sistema de tierra es inadecuado Revise las conexiones en...

Reviews: