Installation manual.
CNC 8060
CNC 8065
2.
MACHINE PA
RAMETERS.
Gen
e
ral machin
e parameters.
·102·
(R
EF
: 1709)
PRBDI1
Number of the input associated with probe 1.
Possible values: From 1 to 1024 for the remote probe / 1 or 2 for the local probe.
Default value: 0 (no probe is connected).
Associated variable: (V.)MPG.PRBDI1
Parameter included in the PROBEDATA table.
This parameter indicates the number of the input that the probe is connected to. For remote
probes, this parameter indicates the digital input number; for local probes, it indicates the
local probe input number.
The digital input will be a physical input of the module or a logic input of the PLC. The PLC
considers logic inputs the inputs that do not exist physically; for example, if inputs 1 through
256 are numbered at the remote modules, the PLC considers logic inputs the ones from 257
to 1024.
Two remote probes cannot be connected to the same module if they are going to be involved
in simultaneous probing operations; for example, a probe in each channel and both making
a probing movement.
PRBDI2
Number of the input associated with probe 2.
Possible values: From 1 to 1024 for the remote probe / 1 or 2 for the local probe.
Default value: 0 (no probe is connected).
Associated variable: (V.)MPG.PRBDI2
Parameter included in the PROBEDATA table.
This parameter indicates the number of the input that the probe is connected to. For remote
probes, this parameter indicates the digital input number; for local probes, it indicates the
local probe input number.
The digital input will be a physical input of the module or a logic input of the PLC. The PLC
considers logic inputs the inputs that do not exist physically; for example, if inputs 1 through
256 are numbered at the remote modules, the PLC considers logic inputs the ones from 257
to 1024.
Two remote probes cannot be connected to the same module if they are going to be involved
in simultaneous probing operations; for example, a probe in each channel and both making
a probing movement.
PRBPULSE1
Logic level to activate probe 1.
Possible values: Positive / Negative.
Default value: Positive.
Associated variable: (V.)MPG.PRBPULSE1
Parameter included in the PROBEDATA table.
This parameter indicates whether the probe functions are active high (24 V or 5 V) or active
low (0V) of the signal provided by the probe. In any case, the probe signal must be at least
20 ms long for the CNC to consider it valid.
PRBPULSE2
Logic level to activate probe 2.
Possible values: Positive / Negative.
Default value: Positive.
Associated variable: (V.)MPG.PRBPULSE2
Parameter included in the PROBEDATA table.
This parameter indicates whether the probe functions are active high (24 V or 5 V) or active
low (0V) of the signal provided by the probe. In any case, the probe signal must be at least
20 ms long for the CNC to consider it valid.
Summary of Contents for CNC 8060
Page 1: ...Ref 1709 8060 8065 CNC Installation manual...
Page 10: ...BLANK PAGE 10...
Page 14: ...BLANK PAGE 14...
Page 20: ...BLANK PAGE 20...
Page 32: ...BLANK PAGE 32...
Page 36: ...BLANK PAGE 36...
Page 38: ...BLANK PAGE 38...
Page 40: ...BLANK PAGE 40...
Page 41: ...PART 1 INSTALLATION MANUAL...
Page 42: ...BLANK PAGE 42...
Page 532: ...Installation manual CNC 8060 CNC 8065 9 CNC VARIABLES 532 REF 1709...
Page 533: ...PART 2 CONCEPTS...
Page 534: ...BLANK PAGE 534...
Page 548: ...Installation manual CNC 8060 CNC 8065 10 GENERAL SETUP Configuration examples 548 REF 1709...
Page 644: ...Installation manual CNC 8060 CNC 8065 14 SUBROUTINES Assistance for subroutines 644 REF 1709...
Page 668: ...Installation manual CNC 8060 CNC 8065 15 HARDWARE Configure the PT100 inputs 668 REF 1709...
Page 697: ...Installation manual CNC 8060 CNC 8065 697 User notes REF 1709...