Administration Manual ip500pbxw – English
138
5.
Select the required timer to be changed and enter the duration. (See table below).
6.
Confirm the new time.
Press the Hands-free Key to finish programming.
Timers Range
Default
setting
Recall on hold
001 – 1800
90 seconds
Recall on transfer
001 – 180
90 seconds
Divert on no answer
01 – 30
11 seconds
Open the door
01 – 30
5 seconds
Door station ring duration
01 – 30
30 seconds
Call park
001 – 600
180 seconds
Ringback time duration
01 – 30
30 seconds
Answer machine delay
01 – 30
10 seconds
Voice Mail message length
30 - 180
120 seconds
Notification delay
60-1800
900 seconds
Notification interval
60-900
300 seconds
-
Recall on Hold:
This is the time that elapses before a call, which has been placed on hold, rings back the
station that put the call on hold.
-
Recall on transfer: This is the time that elapses before a call, which has been transferred and not answered, rings
back the station that attempted the transfer.
-
Divert on no answer: This is the time that elapses before a call ringing at a station, with ’Forward On No Answer’ set,
is forwarded.
-
Open the door:
This is the time that the doorstrike relay will remain open following activation.
-
Door station ring duration:
This is the time that stations will ring when the door station is pressed.
-
Call Park: This is the time that elapses before a call placed on ‘Call Park’ rings back the parked call station
-
Ringback time duration:
This is the time a station will ring when Ringback has been invoked.
-
Ans. Machine delay: This is the time that elapses before an unanswered incoming call is presented with the
Answering Machine greeting.
-
Voicemail message length: This is the maximum length of a message left in a Mailbox or a Greeting for a Mailbox.
-
Notification delay:
This is the delay between receiving a voice mail message and attempting a remote notification
call.
-
Notification Interval: This is the delay after making an unsuccessful remote notification call before attempting
another call.
To reset your system
There are two system reset options available – a warm and a cold reset.
1.
From the Programming station, press
.
2.
Press the Scroll Down Key (
Ô
) until
System
programming
is displayed and select.
3.
Enter the System Programming Password and select
System
.
4.
Press the Scroll Down Key (
Ô
) until
Reset
options
is displayed and select.
5. Select
Reset!
or
Reset
to
default!
WARNING
These are complete system resets, not individual station resets. Selecting ‘Reset!’ (warm reset)
will reset the system and cut off all established calls. Selecting ‘Reset to default!’ (cold reset) will
reset the system, cut off all established calls and remove all programming from the system.