Administration Manual ip500pbxw – English
129
A station placed in Class 4 is restricted to internal and emergency, (112), calls only.
A station can be placed in Class 5 in addition to being in Class 2 or 3. In this case the codes programmed in Table 5 are
allowed.
A station can be placed in Class 6 in addition to being in Class 1, 2 or 3. In this case the codes programmed in Table 6 are
restricted.
The following table shows the types of restriction for the different Classes of Service available:
Type of restriction
Table
Class
No restriction
-
1
Restrict codes in Table 2
Table 2
2
Restrict codes in Table 2 and 3
Table 3
3
Internal and emergency calls only
-
4
Allowed codes that can be combined with Class 2 or 3
Table 5
5
Restricted codes that can be combined Class 1, 2 or 3
Table 6
6
The emergency code is 112. The emergency code is never restricted.
Both Classes 5 and 6 can be associated with the same station.
Class 5 cannot be associated with Class 4 stations.
To set up Class of Service access tables
1.
From the Programming Station, press
2.
Press the Scroll Down Key (
Ô
) until
System
programming
is displayed and select.
3.
Enter the System Programming Password and select
System
.
4.
Press the Scroll Down Key (
Ô
) until
Class
codes
is displayed and select.
5. Select
the
Table
to which you want to assign codes. (Table 2, 3, Allowed Table, or Restricted Table).
6. Select
an
Index
number
and enter the code.
When entering a code an additional option is given on the display of your ip520c. This option is the ‘Any’ key, which when
selected inserts the symbol
‘X’
into the next character of the code (number) you are entering. The symbol
‘X’
will represent
any number (1 to 0).
7. Select
‘Confirm’
when
the code is entered.
Press the Hands-free Key to finish programming.
To restrict Stations during the day
With this feature, you can assign the stations to a Class of Service that will operate when the system is in ‘Day Service’. On
power-up, all stations are in Class 1.
1.
From the Programming Station, press
2.
Press the Scroll Down Key (
Ô
) until
System
programming
is displayed and select.
3.
Enter the System Programming Password and select
Stations
.
4. Select
Restriction
classes
.
5. Select
Day
Class
of
Service
.
6.
Select the Class you want to assign to the Stations, (Class 1 – Class 6).
7.
Select the stations to be entered in this Class.
Press the Hands-free Key to finish programming.
To restrict stations during the night
With this feature, you can assign the stations to a Class of Service that will operate when the system is in ‘Night Service’.
On power-up all Stations are in Class 1.
1.
From the Programming Station, press
2.
Press the Scroll Down Key (
Ô
) until
System
programming
is displayed and select.
3.
Enter the System Programming Password and select
Stations
.