13-42 Logic Rule Boolean 2
Option:
Function:
[77]
Digital input x30/3
[78]
Digital input x30/4
[79]
Digital input x46/1
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input
x46/11
[85]
Digital input
x46/13
[90]
ATEX ETR cur.
warning
Available if
parameter 1-90 Motor
Thermal Protection
is set to
[20] ATEX
ETR
or
[21] Advanced ETR
. If
alarm 164,
ATEX ETR cur.lim.alarm
is active, the
output is 1.
[91]
ATEX ETR cur.
alarm
Available if
is set to
[20] ATEX
ETR
or
[21] Advanced ETR
. If
alarm 166,
ATEX ETR freq.lim.alarm
is active, the
output is 1.
[92]
ATEX ETR freq.
warning
Available if
is set to
[20] ATEX
ETR
or
[21] Advanced ETR
. If
alarm 163,
ATEX ETR cur.lim.warning
is active, the
output is 1.
[93]
ATEX ETR freq.
alarm
Available if
is set to
[20] ATEX
ETR
or
[21] Advanced ETR
. If
warning
165, ATEX ETR freq.lim.warning
is active,
the output is 1.
[94]
RS Flipflop 0
See
parameter group 13-1*
Comparators
.
[95]
RS Flipflop 1
See
parameter group 13-1*
Comparators
.
[96]
RS Flipflop 2
See
parameter group 13-1*
Comparators
.
[97]
RS Flipflop 3
See
parameter group 13-1*
Comparators
.
[98]
RS Flipflop 4
See
parameter group 13-1*
Comparators
.
[99]
RS Flipflop 5
See
parameter group 13-1*
Comparators
.
[100] RS Flipflop 6
See
parameter group 13-1*
Comparators
.
[101] RS Flipflop 7
See
parameter group 13-1*
Comparators
.
[102] Relay 1
[103] Relay 2
13-42 Logic Rule Boolean 2
Option:
Function:
[104] Relay 3
X47/VLT
®
Extended Relay Card MCB
113.
[105] Relay 4
X47/VLT
®
Extended Relay Card MCB
113.
[106] Relay 5
X47/VLT
®
Extended Relay Card MCB
113.
[107] Relay 6
X47/VLT
®
Extended Relay Card MCB
113.
[108] Relay 7
X34/VLT
®
Relay Card MCB 105.
[109] Relay 8
X34/VLT
®
Relay Card MCB 105.
[110] Relay 9
X34/VLT
®
Relay Card MCB 105.
[222] Homing Ok
NOTICE
This option is available only with
software version 48.20 and
newer.
Homing is completed with the
selected homing function
(
parameter 17-80 Homing Function
).
[223] On Target
NOTICE
This option is available only with
software version 48.20 and
newer.
Positioning is completed and the on-
target signal is sent when the actual
position is within
for the duration of
and the
actual speed does not exceed
parameter 3-05 On Reference Window
.
[224] Position Error
NOTICE
This option is available only with
software version 48.20 and
newer.
The position error exceeds the value
in
parameter 4-71 Maximum Position
for the time set in
parameter 4-72 Position Error Timeout
[225] Position Limit
NOTICE
This option is available only with
software version 48.20 and
newer.
The position is outside the limits set
in
parameter 3-06 Minimum Position
and
parameter 3-07 Maximum Position
Parameter Descriptions
Programming Guide
MG33MP02