0-7* Clock Settings
0-70 Date and Time
ExpressionLimit
All set-ups
TRUE
0
TimeO
fDay
0-71 Date Format
ExpressionLimit
1 set-up
TRUE
-
Uint8
0-72 Time Format
ExpressionLimit
1 set-up
TRUE
-
Uint8
0-73 Time Zone Offset
0 min
2 set-ups
FALSE
70
Int16
0-74 DST/Summertime
[0] Off
1 set-up
TRUE
-
Uint8
0-76 DST/Summertime Start
ExpressionLimit
1 set-up
TRUE
0
TimeO
fDay
0-77 DST/Summertime End
ExpressionLimit
1 set-up
TRUE
0
TimeO
fDay
0-79 Clock Fault
ExpressionLimit
1 set-up
TRUE
-
Uint8
0-81 Working Days
ExpressionLimit
1 set-up
TRUE
-
Uint8
0-82 Additional Working Days
ExpressionLimit
1 set-up
TRUE
0
TimeO
fDay
0-83 Additional Non-Working Days
ExpressionLimit
1 set-up
TRUE
0
TimeO
fDay
0-84 Time for Fieldbus
0 N/A
All set-ups
TRUE
0
Uint32
0-85 Summer Time Start for Fieldbus
0 N/A
All set-ups
TRUE
0
Uint32
0-86 Summer Time End for Fieldbus
0 N/A
All set-ups
TRUE
0
Uint32
0-89 Date and Time Readout
0 N/A
All set-ups
TRUE
0
VisStr[
25]
5.2.2 1-** Load and Motor
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
1-0* General Settings
1-00 Configuration Mode
ExpressionLimit
All set-ups
TRUE
-
Uint8
1-01 Motor Control Principle
ExpressionLimit
All set-ups
FALSE
-
Uint8
1-02 Flux Motor Feedback Source
[1] 24V encoder
All set-ups
x
FALSE
-
Uint8
1-03 Torque Characteristics
[0] Constant torque
All set-ups
TRUE
-
Uint8
1-04 Overload Mode
[0] High torque
All set-ups
FALSE
-
Uint8
1-05 Local Mode Configuration
[2] As mode par 1-00
All set-ups
TRUE
-
Uint8
1-06 Clockwise Direction
[0] Normal
All set-ups
FALSE
-
Uint8
1-07 Motor Angle Offset Adjust
[0] Manual
All set-ups
x
FALSE
-
Uint8
1-1* Special Settings
1-10 Motor Construction
[0] Asynchron
All set-ups
FALSE
-
Uint8
1-11 Motor Model
ExpressionLimit
All set-ups
x
FALSE
-
Uint8
1-14 Damping Gain
140 %
All set-ups
TRUE
0
Int16
1-15 Low Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-16 High Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-17 Voltage filter time const.
ExpressionLimit
All set-ups
TRUE
-3
Uint16
1-18 Min. Current at No Load
0 %
All set-ups
TRUE
0
Uint16
1-2* Motor Data
1-20 Motor Power [kW]
ExpressionLimit
All set-ups
FALSE
1
Uint32
1-21 Motor Power [HP]
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-22 Motor Voltage
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-23 Motor Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-24 Motor Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-25 Motor Nominal Speed
ExpressionLimit
All set-ups
FALSE
67
Uint16
1-26 Motor Cont. Rated Torque
ExpressionLimit
All set-ups
FALSE
-1
Uint32
1-29 Automatic Motor Adaptation (AMA)
[0] Off
All set-ups
FALSE
-
Uint8
1-3* Adv. Motor Data
1-30 Stator Resistance (Rs)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
Parameter Lists
VLT
®
AutomationDrive FC 301/302
264
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02
5
5