1-94 ATEX ETR cur.lim. speed reduction
0 %
2 set-ups
x
TRUE
-1
Uint16
1-95 Thermistor Sensor Type
[0] KTY Sensor 1
All set-ups
TRUE
-
Uint8
1-96 Thermistor Sensor Resource
[0] None
All set-ups
TRUE
-
Uint8
1-97 Thermistor Threshold level
80 °C
1 set-up
TRUE
100
Int16
1-98 ATEX ETR interpol. points freq.
ExpressionLimit
1 set-up
x
TRUE
-1
Uint16
1-99 ATEX ETR interpol points current
ExpressionLimit
2 set-ups
x
TRUE
0
Uint16
5.2.3 2-** Brakes
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
2-0* DC-Brake
2-00 DC Hold Current
50 %
All set-ups
TRUE
0
Uint8
2-01 DC Brake Current
50 %
All set-ups
TRUE
0
Uint16
2-02 DC Braking Time
10 s
All set-ups
TRUE
-1
Uint16
2-03 DC Brake Cut In Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
2-04 DC Brake Cut In Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
2-05 Maximum Reference
MaxReference (P303)
All set-ups
TRUE
-3
Int32
2-06 Parking Current
50 %
All set-ups
TRUE
0
Uint16
2-07 Parking Time
3 s
All set-ups
TRUE
-1
Uint16
2-1* Brake Energy Funct.
2-10 Brake Function
ExpressionLimit
All set-ups
TRUE
-
Uint8
2-11 Brake Resistor (ohm)
ExpressionLimit
All set-ups
TRUE
0
Uint16
2-12 Brake Power Limit (kW)
ExpressionLimit
All set-ups
TRUE
0
Uint32
2-13 Brake Power Monitoring
[0] Off
All set-ups
TRUE
-
Uint8
2-15 Brake Check
[0] Off
All set-ups
TRUE
-
Uint8
2-16 AC brake Max. Current
100 %
All set-ups
TRUE
-1
Uint32
2-17 Over-voltage Control
[0] Disabled
All set-ups
TRUE
-
Uint8
2-18 Brake Check Condition
[0] At Power Up
All set-ups
TRUE
-
Uint8
2-19 Over-voltage Gain
100 %
All set-ups
TRUE
0
Uint16
2-2* Mechanical Brake
2-20 Release Brake Current
ImaxVLT (P1637)
All set-ups
TRUE
-2
Uint32
2-21 Activate Brake Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
2-22 Activate Brake Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
2-23 Activate Brake Delay
0 s
All set-ups
TRUE
-1
Uint8
2-24 Stop Delay
0 s
All set-ups
TRUE
-1
Uint8
2-25 Brake Release Time
0.20 s
All set-ups
TRUE
-2
Uint16
2-26 Torque Ref
0 %
All set-ups
TRUE
-2
Int16
2-27 Torque Ramp Up Time
0.2 s
All set-ups
TRUE
-1
Uint8
2-28 Gain Boost Factor
1 N/A
All set-ups
TRUE
-2
Uint16
2-29 Torque Ramp Down Time
0 s
All set-ups
TRUE
-1
Uint8
2-3* Adv. Mech Brake
2-30 Position P Start Proportional Gain
0.0000 N/A
All set-ups
TRUE
-4
Uint32
2-31 Speed PID Start Proportional Gain
0.0150 N/A
All set-ups
TRUE
-4
Uint32
2-32 Speed PID Start Integral Time
200.0 ms
All set-ups
TRUE
-4
Uint32
2-33 Speed PID Start Lowpass Filter Time
10.0 ms
All set-ups
TRUE
-4
Uint16
5.2.4 3-** Reference / Ramps
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
3-0* Reference Limits
3-00 Reference Range
ExpressionLimit
All set-ups
TRUE
-
Uint8
Parameter Lists
VLT
®
AutomationDrive FC 301/302
266
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02