12-99 Media Counters
0 N/A
All set-ups
TRUE
0
Uint32
5.3.13 13-** Smart Logic
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
13-0* SLC Settings
13-00 SL Controller Mode
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-01 Start Event
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-02 Stop Event
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-03 Reset SLC
[0] Do not reset SLC
All set-ups
TRUE
-
Uint8
13-1* Comparators
13-10 Comparator Operand
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-11 Comparator Operator
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-12 Comparator Value
ExpressionLimit
2 set-ups
TRUE
-3
Int32
13-1* RS Flip Flops
13-15 RS-FF Operand S
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-16 RS-FF Operand R
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-2* Timers
13-20 SL Controller Timer
ExpressionLimit
1 set-up
TRUE
-3
TimD
13-4* Logic Rules
13-40 Logic Rule Boolean 1
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-41 Logic Rule Operator 1
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-42 Logic Rule Boolean 2
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-43 Logic Rule Operator 2
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-44 Logic Rule Boolean 3
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-5* States
13-51 SL Controller Event
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-52 SL Controller Action
ExpressionLimit
2 set-ups
TRUE
-
Uint8
13-9* User Defined Alerts
13-90 Alert Trigger
[0] False
2 set-ups
TRUE
-
Uint8
13-91 Alert Action
[0] Info
2 set-ups
TRUE
-
Uint8
13-92 Alert Text
ExpressionLimit
2 set-ups
TRUE
0
VisStr[
20]
13-9* User Defined Readouts
13-97 Alert Alarm Word
0 N/A
All set-ups
FALSE
0
Uint32
13-98 Alert Warning Word
0 N/A
All set-ups
FALSE
0
Uint32
13-99 Alert Status Word
0 N/A
All set-ups
FALSE
0
Uint32
5.3.14 14-** Special Functions
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
14-0* Inverter Switching
14-00 Switching Pattern
[1] SFAVM
All set-ups
TRUE
-
Uint8
14-01 Switching Frequency
ExpressionLimit
All set-ups
TRUE
-
Uint8
14-03 Overmodulation
ExpressionLimit
All set-ups
FALSE
-
Uint8
14-04 Acoustic Noise Reduction
[0] Off
All set-ups
TRUE
-
Uint8
14-06 Dead Time Compensation
[1] On
All set-ups
TRUE
-
Uint8
14-1* Mains Failure
14-10 Mains Failure
[0] No function
All set-ups
TRUE
-
Uint8
14-11 Mains Fault Voltage Level
ExpressionLimit
All set-ups
TRUE
0
Uint16
14-12 Response to Mains Imbalance
[0] Trip
All set-ups
TRUE
-
Uint8
Parameter Lists
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
307