32-62 Integral factor
0 N/A
2 set-ups
TRUE
0
Uint32
32-63 Limit Value for Integral Sum
1000 N/A
2 set-ups
TRUE
0
Uint16
32-64 PID Bandwidth
1000 N/A
2 set-ups
TRUE
0
Uint16
32-65 Velocity Feed-Forward
0 N/A
2 set-ups
TRUE
0
Uint32
32-66 Acceleration Feed-Forward
0 N/A
2 set-ups
TRUE
0
Uint32
32-67 Max. Tolerated Position Error
20000 N/A
2 set-ups
TRUE
0
Uint32
32-68 Reverse Behavior for Slave
[0] Reversing allowed
2 set-ups
TRUE
-
Uint8
32-69 Sampling Time for PID Control
1 ms
2 set-ups
TRUE
-3
Uint16
32-70 Scan Time for Profile Generator
1 ms
2 set-ups
TRUE
-3
Uint8
32-71 Size of the Control Window (Activation)
0 N/A
2 set-ups
TRUE
0
Uint32
32-72 Size of the Control Window (Deactiv.)
0 N/A
2 set-ups
TRUE
0
Uint32
32-73 Integral limit filter time
0 ms
2 set-ups
TRUE
-3
Int16
32-74 Position error filter time
0 ms
2 set-ups
TRUE
-3
Int16
32-8* Velocity & Accel.
32-80 Maximum Velocity (Encoder)
1500 RPM
2 set-ups
TRUE
67
Uint32
32-81 Shortest Ramp
1 s
2 set-ups
TRUE
-3
Uint32
32-82 Ramp Type
[0] Linear
2 set-ups
TRUE
-
Uint8
32-83 Velocity Resolution
100 N/A
2 set-ups
TRUE
0
Uint32
32-84 Default Velocity
50 N/A
2 set-ups
TRUE
0
Uint32
32-85 Default Acceleration
50 N/A
2 set-ups
TRUE
0
Uint32
32-86 Acc. up for limited jerk
100 ms
2 set-ups
TRUE
-3
Uint32
32-87 Acc. down for limited jerk
0 ms
2 set-ups
TRUE
-3
Uint32
32-88 Dec. up for limited jerk
0 ms
2 set-ups
TRUE
-3
Uint32
32-89 Dec. down for limited jerk
0 ms
2 set-ups
TRUE
-3
Uint32
32-9* Development
32-90 Debug Source
[0] Controlcard
2 set-ups
TRUE
-
Uint8
5.2.24 33-** MCO Adv. Settings
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
33-0* Home Motion
33-00 Force HOME
[0] Home not forced
2 set-ups
TRUE
-
Uint8
33-01 Zero Point Offset from Home Pos.
0 N/A
2 set-ups
TRUE
0
Int32
33-02 Ramp for Home Motion
10 N/A
2 set-ups
TRUE
0
Uint32
33-03 Velocity of Home Motion
10 N/A
2 set-ups
TRUE
0
Int32
33-04 Behaviour during HomeMotion
[0] Revers and index
2 set-ups
TRUE
-
Uint8
33-1* Synchronization
33-10 Sync Factor Master
1 N/A
2 set-ups
TRUE
0
Int32
33-11 Sync Factor Slave
1 N/A
2 set-ups
TRUE
0
Int32
33-12 Position Offset for Synchronization
0 N/A
2 set-ups
TRUE
0
Int32
33-13 Accuracy Window for Position Sync.
1000 N/A
2 set-ups
TRUE
0
Int32
33-14 Relative Slave Velocity Limit
0 %
2 set-ups
TRUE
0
Uint8
33-15 Marker Number for Master
1 N/A
2 set-ups
TRUE
0
Uint16
33-16 Marker Number for Slave
1 N/A
2 set-ups
TRUE
0
Uint16
33-17 Master Marker Distance
4096 N/A
2 set-ups
TRUE
0
Uint32
33-18 Slave Marker Distance
4096 N/A
2 set-ups
TRUE
0
Uint32
33-19 Master Marker Type
[0] Encoder Z positive
2 set-ups
TRUE
-
Uint8
33-20 Slave Marker Type
[0] Encoder Z positive
2 set-ups
TRUE
-
Uint8
33-21 Master Marker Tolerance Window
0 N/A
2 set-ups
TRUE
0
Uint32
33-22 Slave Marker Tolerance Window
0 N/A
2 set-ups
TRUE
0
Uint32
33-23 Start Behaviour for Marker Sync
[0] Leading marker
2 set-ups
TRUE
-
Uint16
33-24 Marker Number for Fault
10 N/A
2 set-ups
TRUE
0
Uint16
33-25 Marker Number for Ready
1 N/A
2 set-ups
TRUE
0
Uint16
33-26 Velocity Filter
0 us
2 set-ups
TRUE
-6
Int32
Parameter Lists
VLT
®
AutomationDrive FC 301/302
286