13-42 Logic Rule Boolean 2
Option:
Function:
[226] Touch on Target
NOTICE
This option is available only with
software version 48.20 and
newer.
Target position is reached in touch
probe position mode.
[227] Touch Activated
NOTICE
This option is available only with
software version 48.20 and
newer.
Touch probe positioning active. The
frequency converter monitors the
touch probe sensor input.
3.13.8 13-43 Logic Rule Operator 2
13-43 Logic Rule Operator 2
Option:
Function:
Select the 2
nd
logical operator to be used on
the boolean input calculated in:
•
Parameter 13-40 Logic Rule Boolean
1
.
•
Parameter 13-41 Logic Rule Operator
1
.
•
Parameter 13-42 Logic Rule Boolean
2
.
[13-44] signifies the boolean input of
parameter 13-44 Logic Rule Boolean 3
.
[13-40/13-42] signifies the boolean input
calculated in:
•
Parameter 13-40 Logic Rule Boolean
1
.
•
Parameter 13-41 Logic Rule Operator
1
.
•
Parameter 13-42 Logic Rule Boolean
2
.
[0] DISABLED
[1] AND
[2] OR
[3] AND NOT
[4] OR NOT
[5] NOT AND
[6] NOT OR
[7] NOT AND
NOT
[8] NOT OR NOT
3.13.9 13-44 Logic Rule Boolean 3
13-44 Logic Rule Boolean 3
Array [6]
Option:
Function:
[0]
False
Select the 3
rd
boolean (true or false)
input for the selected logic rule. See
parameter 13-01 Start Event
(options
[0] False
–
[61] Logic rule 5
) and
(options
[70] SL Time-out 3
–
[75] Start command
given
) for more information.
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current
range
[8]
Below I low
[9]
Above I high
[10]
Out of speed
range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb.
range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of
range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
Parameter Descriptions
VLT
®
AutomationDrive FC 301/302
182
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02
3
3
Summary of Contents for VLT AutomationDrive FC 302