2-06 Parking Current
50 %
All set-ups
TRUE
0
Uint16
2-07 Parking Time
3 s
All set-ups
TRUE
-1
Uint16
2-1* Brake Energy Funct.
2-10 Brake Function
ExpressionLimit
All set-ups
TRUE
-
Uint8
2-11 Brake Resistor (ohm)
ExpressionLimit
All set-ups
TRUE
0
Uint16
2-12 Brake Power Limit (kW)
ExpressionLimit
All set-ups
TRUE
0
Uint32
2-13 Brake Power Monitoring
[0] Off
All set-ups
TRUE
-
Uint8
2-15 Brake Check
[0] Off
All set-ups
TRUE
-
Uint8
2-16 AC brake Max. Current
100 %
All set-ups
TRUE
-1
Uint32
2-17 Over-voltage Control
[0] Disabled
All set-ups
TRUE
-
Uint8
2-18 Brake Check Condition
[0] At Power Up
All set-ups
TRUE
-
Uint8
2-19 Over-voltage Gain
100 %
All set-ups
TRUE
0
Uint16
2-2* Mechanical Brake
2-20 Release Brake Current
ImaxVLT (P1637)
All set-ups
TRUE
-2
Uint32
2-21 Activate Brake Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
2-22 Activate Brake Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
2-23 Activate Brake Delay
0 s
All set-ups
TRUE
-1
Uint8
2-24 Stop Delay
0 s
All set-ups
TRUE
-1
Uint8
2-25 Brake Release Time
0.20 s
All set-ups
TRUE
-2
Uint16
2-26 Torque Ref
0 %
All set-ups
TRUE
-2
Int16
2-27 Torque Ramp Up Time
0.2 s
All set-ups
TRUE
-1
Uint8
2-28 Gain Boost Factor
1 N/A
All set-ups
TRUE
-2
Uint16
2-29 Torque Ramp Down Time
0 s
All set-ups
TRUE
-1
Uint8
2-3* Adv. Mech Brake
2-30 Position P Start Proportional Gain
0.0500 N/A
All set-ups
TRUE
-4
Uint32
2-31 Speed PID Start Proportional Gain
0.0500 N/A
All set-ups
TRUE
-4
Uint32
2-32 Speed PID Start Integral Time
20.0 ms
All set-ups
TRUE
-4
Uint32
2-33 Speed PID Start Lowpass Filter Time
2.0 ms
All set-ups
TRUE
-4
Uint16
2-34 Zero Speed Position P Proportional Gain
0.0000 N/A
All set-ups
TRUE
-4
Uint32
5.3.4 3-** Reference / Ramps
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
3-0* Reference Limits
3-00 Reference Range
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-01 Reference/Feedback Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-02 Minimum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-03 Maximum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-04 Reference Function
[0] Sum
All set-ups
TRUE
-
Uint8
3-05 On Reference Window
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-06 Minimum Position
-100000 CustomRea-
doutUnit2
All set-ups
TRUE
0
Int32
3-07 Maximum Position
100000 CustomRea-
doutUnit2
All set-ups
TRUE
0
Int32
3-08 On Target Window
5 CustomReadoutUnit2
All set-ups
TRUE
0
Int32
3-09 On Target Time
1 ms
All set-ups
TRUE
-3
Uint16
3-1* References
3-10 Preset Reference
0 %
All set-ups
TRUE
-2
Int16
3-11 Jog Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
3-12 Catch up/slow Down Value
0 %
All set-ups
TRUE
-2
Int16
3-13 Reference Site
[0] Linked to Hand / Auto
All set-ups
TRUE
-
Uint8
3-14 Preset Relative Reference
0 %
All set-ups
TRUE
-2
Int32
3-15 Reference Resource 1
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-16 Reference Resource 2
ExpressionLimit
All set-ups
TRUE
-
Uint8
Parameter Lists
VLT
®
AutomationDrive FC 301/302
296