3-01 Reference/Feedback Unit
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-02 Minimum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-03 Maximum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-04 Reference Function
[0] Sum
All set-ups
TRUE
-
Uint8
3-1* References
3-10 Preset Reference
0 %
All set-ups
TRUE
-2
Int16
3-11 Jog Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
3-12 Catch up/slow Down Value
0 %
All set-ups
TRUE
-2
Int16
3-13 Reference Site
[0] Linked to Hand / Auto
All set-ups
TRUE
-
Uint8
3-14 Preset Relative Reference
0 %
All set-ups
TRUE
-2
Int32
3-15 Reference Resource 1
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-16 Reference Resource 2
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-17 Reference Resource 3
ExpressionLimit
All set-ups
TRUE
-
Uint8
3-18 Relative Scaling Reference Resource
[0] No function
All set-ups
TRUE
-
Uint8
3-19 Jog Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
3-4* Ramp 1
3-40 Ramp 1 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-41 Ramp 1 Ramp Up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-42 Ramp 1 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-45 Ramp 1 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-46 Ramp 1 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-47 Ramp 1 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-48 Ramp 1 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-5* Ramp 2
3-50 Ramp 2 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-51 Ramp 2 Ramp Up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-52 Ramp 2 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-55 Ramp 2 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-56 Ramp 2 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-57 Ramp 2 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-58 Ramp 2 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-6* Ramp 3
3-60 Ramp 3 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-61 Ramp 3 Ramp up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-62 Ramp 3 Ramp down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-65 Ramp 3 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-66 Ramp 3 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-67 Ramp 3 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-68 Ramp 3 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-7* Ramp 4
3-70 Ramp 4 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-71 Ramp 4 Ramp up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-72 Ramp 4 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-75 Ramp 4 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-76 Ramp 4 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-77 Ramp 4 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-78 Ramp 4 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-8* Other Ramps
3-80 Jog Ramp Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-81 Quick Stop Ramp Time
ExpressionLimit
2 set-ups
TRUE
-2
Uint32
3-82 Quick Stop Ramp Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-83 Quick Stop S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-84 Quick Stop S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-89 Ramp Lowpass Filter Time
1 ms
All set-ups
TRUE
-4
Uint16
3-9* Digital Pot.Meter
3-90 Step Size
0.10 %
All set-ups
TRUE
-2
Uint16
Parameter Lists
Programming Guide
MG33MP02