4-7* Position Monitor
4-70 Position Error Function
[0] Disabled
All set-ups
TRUE
-
Uint8
4-71 Maximum Position Error
1000 CustomReadoutUnit2
All set-ups
TRUE
0
Int32
4-72 Position Error Timeout
0.100 s
All set-ups
TRUE
-3
Uint16
4-73 Position Limit Function
[3] Abs. Pos. Mode Stop
All set-ups
TRUE
-
Uint8
4-74 Start Fwd/Rev Function
[0] Stop
All set-ups
TRUE
-
Uint8
4-75 Touch Timout
6000.0 s
All set-ups
TRUE
-1
Uint16
4-8* Power Limit
4-80 Power Limit Func. Motor Mode
[0] Disabled
All set-ups
x
TRUE
-
Uint8
4-81 Power Limit Func. Generator Mode
[0] Disabled
All set-ups
x
TRUE
-
Uint8
4-82 Power Limit Motor Mode
100.0 %
All set-ups
x
TRUE
-1
Uint16
4-83 Power Limit Generator Mode
100.0 %
All set-ups
x
TRUE
-1
Uint16
4-9* Directional Limits
4-90 Directional Limit Mode
[0] Disabled
All set-ups
TRUE
-
Uint8
4-91 Positive Speed Limit [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-92 Positive Speed Limit [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-93 Negative Speed Limit [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-94 Negative Speed Limit [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-95 Positive Torque limit
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-96 Negative Torque limit
ExpressionLimit
All set-ups
TRUE
-1
Uint16
5.3.6 5-** Digital In/Out
Par-
ameter #
Parameter description
Default value
4 set-up
FC 302
only
Change
during
operation
Conversi
on index
Type
5-0* Digital I/O mode
5-00
Digital I/O Mode
[0] PNP
All set-ups
FALSE
-
Uint8
5-01
Terminal 27 Mode
[0] Input
All set-ups
TRUE
-
Uint8
5-02
Terminal 29 Mode
[0] Input
All set-ups
x
TRUE
-
Uint8
5-1* Digital Inputs
5-10
Terminal 18 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-11
Terminal 19 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-12
Terminal 27 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-13
Terminal 29 Digital Input
ExpressionLimit
All set-ups
x
TRUE
-
Uint8
5-14
Terminal 32 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-15
Terminal 33 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-16
Terminal X30/2 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-17
Terminal X30/3 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-18
Terminal X30/4 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-19
Terminal 37 Safe Stop
ExpressionLimit
1 set-up
TRUE
-
Uint8
5-20
Terminal X46/1 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-21
Terminal X46/3 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-22
Terminal X46/5 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-23
Terminal X46/7 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-24
Terminal X46/9 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-25
Terminal X46/11 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-26
Terminal X46/13 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-31
Terminal 29 Digital Output
ExpressionLimit
All set-ups
x
TRUE
-
Uint8
5-32
Term X30/6 Digi Out (MCB 101)
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-33
Term X30/7 Digi Out (MCB 101)
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-4* Relays
Parameter Lists
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
299
5
5