15-76 Option in Slot C1/E1
0 N/A
All set-ups
FALSE
0
VisStr[
30]
15-77 Slot C1/E1 Option SW Version
0 N/A
All set-ups
FALSE
0
VisStr[
20]
15-8* Operating Data II
15-80 Fan Running Hours
0 h
All set-ups
TRUE
74
Uint32
15-81 Preset Fan Running Hours
0 h
All set-ups
TRUE
74
Uint32
15-89 Configuration Change Counter
0 N/A
All set-ups
FALSE
0
Uint16
15-9* Parameter Info
15-92 Defined Parameters
0 N/A
All set-ups
FALSE
0
Uint16
15-93 Modified Parameters
0 N/A
All set-ups
FALSE
0
Uint16
15-98 Drive Identification
0 N/A
All set-ups
FALSE
0
VisStr[
40]
15-99 Parameter Metadata
0 N/A
All set-ups
FALSE
0
Uint16
5.2.16 16-** Data Readouts
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
16-0* General Status
16-00 Control Word
0 N/A
All set-ups
FALSE
0
V2
16-01 Reference [Unit]
0 ReferenceFeedbackUnit
All set-ups
FALSE
-3
Int32
16-02 Reference %
0 %
All set-ups
FALSE
-1
Int16
16-03 Status Word
0 N/A
All set-ups
FALSE
0
V2
16-05 Main Actual Value [%]
0 %
All set-ups
FALSE
-2
N2
16-06 Actual Position
0 CustomReadoutUnit2
All set-ups
FALSE
0
Int32
16-09 Custom Readout
0 CustomReadoutUnit
All set-ups
FALSE
-2
Int32
16-1* Motor Status
16-10 Power [kW]
0 kW
All set-ups
FALSE
1
Int32
16-11 Power [hp]
0 hp
All set-ups
FALSE
-2
Int32
16-12 Motor Voltage
0 V
All set-ups
FALSE
-1
Uint16
16-13 Frequency
0 Hz
All set-ups
FALSE
-1
Uint16
16-14 Motor current
0 A
All set-ups
FALSE
-2
Int32
16-15 Frequency [%]
0 %
All set-ups
FALSE
-2
N2
16-16 Torque [Nm]
0 Nm
All set-ups
FALSE
-1
Int16
16-17 Speed [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-18 Motor Thermal
0 %
All set-ups
FALSE
0
Uint8
16-19 Thermistor Sensor Temperature
0 °C
All set-ups
FALSE
100
Int16
16-20 Motor Angle
0 N/A
All set-ups
TRUE
0
Uint16
16-21 Torque [%] High Res.
0 %
All set-ups
FALSE
-1
Int16
16-22 Torque [%]
0 %
All set-ups
FALSE
0
Int16
16-23 Motor Shaft Power [kW]
0 kW
All set-ups
TRUE
1
Int32
16-24 Calibrated Stator Resistance
0.0000 Ohm
All set-ups
x
TRUE
-4
Uint32
16-25 Torque [Nm] High
0 Nm
All set-ups
FALSE
-1
Int32
16-3* Drive Status
16-30 DC Link Voltage
0 V
All set-ups
FALSE
0
Uint16
16-31 System Temp.
0 °C
All set-ups
x
TRUE
100
Int8
16-32 Brake Energy /s
0 kW
All set-ups
FALSE
0
Uint32
16-33 Brake Energy Average
0 kW
All set-ups
FALSE
0
Uint32
16-34 Heatsink Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-35 Inverter Thermal
0 %
All set-ups
FALSE
0
Uint8
16-36 Inv. Nom. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-37 Inv. Max. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-38 SL Controller State
0 N/A
All set-ups
FALSE
0
Uint8
16-39 Control Card Temp.
0 °C
All set-ups
FALSE
100
Uint8
Parameter Lists
VLT
®
AutomationDrive FC 301/302
280