1-53 Model Shift Frequency
ExpressionLimit
All set-ups
x
FALSE
-1
Uint16
1-54 Voltage reduction in fieldweakening
0 V
All set-ups
FALSE
0
Uint8
1-55 U/f Characteristic - U
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-56 U/f Characteristic - F
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-57 Torque Estimation Time Constant
150 ms
All set-ups
TRUE
-3
Uint16
1-58 Flying Start Test Pulses Current
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-59 Flying Start Test Pulses Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-6* Load Depen. Setting
1-60 Low Speed Load Compensation
100 %
All set-ups
TRUE
0
Int16
1-61 High Speed Load Compensation
100 %
All set-ups
TRUE
0
Int16
1-62 Slip Compensation
ExpressionLimit
All set-ups
TRUE
0
Int16
1-63 Slip Compensation Time Constant
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-64 Resonance Damping
ExpressionLimit
All set-ups
TRUE
0
Uint16
1-65 Resonance Damping Time Constant
5 ms
All set-ups
TRUE
-3
Uint8
1-66 Min. Current at Low Speed
ExpressionLimit
All set-ups
x
TRUE
0
Uint32
1-67 Load Type
[0] Passive load
All set-ups
x
TRUE
-
Uint8
1-68 Motor Inertia
0 kgm²
All set-ups
x
FALSE
-4
Uint32
1-69 System Inertia
ExpressionLimit
All set-ups
x
FALSE
-4
Uint32
1-7* Start Adjustments
1-70 Start Mode
[0] Rotor Detection
All set-ups
TRUE
-
Uint8
1-71 Start Delay
0 s
All set-ups
TRUE
-1
Uint8
1-72 Start Function
[2] Coast/delay time
All set-ups
TRUE
-
Uint8
1-73 Flying Start
ExpressionLimit
All set-ups
FALSE
-
Uint8
1-74 Start Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
1-75 Start Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-76 Start Current
0 A
All set-ups
TRUE
-2
Uint32
1-8* Stop Adjustments
1-80 Function at Stop
[0] Coast
All set-ups
TRUE
-
Uint8
1-81 Min Speed for Function at Stop [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
1-82 Min Speed for Function at Stop [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-83 Precise Stop Function
[0] Precise ramp stop
All set-ups
FALSE
-
Uint8
1-84 Precise Stop Counter Value
100000 N/A
All set-ups
TRUE
0
Uint32
1-85 Precise Stop Speed Compensation Delay
10 ms
All set-ups
TRUE
-3
Uint8
1-9* Motor Temperature
1-90 Motor Thermal Protection
ExpressionLimit
All set-ups
TRUE
-
Uint8
1-91 Motor External Fan
ExpressionLimit
All set-ups
TRUE
-
Uint8
1-93 Thermistor Resource
[0] None
All set-ups
TRUE
-
Uint8
1-94 ATEX ETR cur.lim. speed reduction
0 %
2 set-ups
x
TRUE
-1
Uint16
1-95 Thermistor Sensor Type
[0] KTY Sensor 1
All set-ups
TRUE
-
Uint8
1-96 Thermistor Sensor Resource
[0] None
All set-ups
TRUE
-
Uint8
1-97 Thermistor Threshold level
80 °C
1 set-up
TRUE
100
Int16
1-98 ATEX ETR interpol. points freq.
ExpressionLimit
1 set-up
x
TRUE
-1
Uint16
1-99 ATEX ETR interpol points current
ExpressionLimit
2 set-ups
x
TRUE
0
Uint16
5.3.3 2-** Brakes
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
2-0* DC-Brake
2-00 DC Hold Current
50 %
All set-ups
TRUE
0
Uint8
2-01 DC Brake Current
50 %
All set-ups
TRUE
0
Uint16
2-02 DC Braking Time
10 s
All set-ups
TRUE
-1
Uint16
2-03 DC Brake Cut In Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
2-04 DC Brake Cut In Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
2-05 Maximum Reference
MaxReference (P303)
All set-ups
TRUE
-3
Int32
Parameter Lists
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
295
5
5