130BA076.10
(RPM)
Ref.
Low freq.
P 5-50/
P 5-55
Input
(Hz)
High
ref.
value
P 5-53/
p 5-58
High freq.
P 5-51/
P 5-56
Low
ref.
value
P 5-52/
p 5-57
Illustration 3.39 Pulse Input
5-50 Term. 29 Low Frequency
Range:
Function:
100
Hz
*
[0 - 110000
Hz]
Enter the low frequency limit
corresponding to the low motor shaft
speed (that is low reference value) in
parameter 5-52 Term. 29 Low Ref./Feedb.
Value
. Refer to
5-51 Term. 29 High Frequency
Range:
Function:
Size
related
*
[0 - 110000
Hz]
Enter the high frequency limit
corresponding to the high motor shaft
speed (that is high reference value) in
parameter 5-53 Term. 29 High Ref./
Feedb. Value
.
5-52 Term. 29 Low Ref./Feedb. Value
Range:
Function:
0 ReferenceFeed-
backUnit
*
[-999999.999 -
999999.999
ReferenceFeed-
backUnit]
Enter the low reference
value limit for the motor
shaft speed [RPM]. This is
also the lowest feedback
value, see also
parameter 5-57 Term. 33 Low
Ref./Feedb. Value
. Set
terminal 29 to digital input
(
=
[0] input
(default)
and
= applicable
value).
5-53 Term. 29 High Ref./Feedb. Value
Range:
Function:
Size
related
*
[-999999.999 -
999999.999
ReferenceFeed-
backUnit]
Enter the high reference value
[RPM] for the motor shaft speed
and the high feedback value, see
also
parameter 5-58 Term. 33 High
Ref./Feedb. Value
. Select terminal 29
as a digital input
5-53 Term. 29 High Ref./Feedb. Value
Range:
Function:
(
parameter 5-02 Terminal 29 Mode
=
[0] input
(default) and
parameter 5-13 Terminal 29 Digital
Input
= applicable value).
This parameter is available for FC
302 only.
5-54 Pulse Filter Time Constant #29
Range:
Function:
100
ms
*
[1 - 1000
ms]
Enter the pulse filter time constant. The
pulse filter dampens oscillations of the
feedback signal, if there is much noise in
the system this is an advantage. A high
time constant value results in better
dampening but also increases the time
delay through the filter.
5-55 Term. 33 Low Frequency
Range:
Function:
100 Hz
*
[0 - 110000
Hz]
Enter the low frequency corresponding
to the low motor shaft speed (that is
low reference value) in
parameter 5-57 Term. 33 Low Ref./Feedb.
Value
5-56 Term. 33 High Frequency
Range:
Function:
Size
related
*
[0 - 110000
Hz]
Enter the high frequency
corresponding to the high motor
shaft speed (that is high reference
value) in
5-57 Term. 33 Low Ref./Feedb. Value
Range:
Function:
0 ReferenceFeed-
backUnit
*
[-999999.999 -
999999.999
ReferenceFeed-
backUnit]
Enter the low reference
value [RPM] for the motor
shaft speed. This is also
the low feedback value,
see also
parameter 5-52 Term. 29
Low Ref./Feedb. Value
5-58 Term. 33 High Ref./Feedb. Value
Range:
Function:
Size
related
*
[-999999.999 -
999999.999
ReferenceFeed-
backUnit]
Enter the high reference value
[RPM] for the motor shaft
speed. See also
parameter 5-53 Term. 29 High
Ref./Feedb. Value
.
Parameter Descriptions
Programming Guide
MG33MP02