5-18 Terminal X30/4 Digital Input
Option:
Function:
Functions are described in
parameter group 5-1* Digital
Inputs
.
[1]
Reset
[2]
Coast inverse
[3]
Coast and reset inv
[4]
Quick stop inverse
[5]
DC-brake inverse
[6]
Stop inverse
[8]
Start
[9]
Latched start
[10]
Reversing
[11]
Start reversing
[12]
Enable start forward
[13]
Enable start reverse
[14]
Jog
[15]
Preset reference on
[16]
Preset ref bit 0
[17]
Preset ref bit 1
[18]
Preset ref bit 2
[19]
Freeze reference
[20]
Freeze output
[21]
Speed up
[22]
Speed down
[23]
Set-up select bit 0
[24]
Set-up select bit 1
[28]
Catch up
[29]
Slow down
[34]
Ramp bit 0
[35]
Ramp bit 1
[44]
Restart Drive
[51]
External Interlock
[55]
DigiPot increase
[56]
DigiPot decrease
[57]
DigiPot clear
[58]
DigiPot Hoist
[62]
Reset Counter A
[65]
Reset Counter B
[70]
Mech. Brake Feedb.
[71]
Mech. Brake Feedb. Inv.
[72]
PID error inverse
[73]
PID reset I part
[74]
PID enable
[75]
MCO Specific
[78]
Reset Maint. Word
[80]
PTC Card 1
[91]
Profidrive OFF2
[92]
Profidrive OFF3
[94]
Light Load Detection
[96]
Mains Loss
[97]
Mains Loss Inverse
[98]
Start edge triggered
5-18 Terminal X30/4 Digital Input
Option:
Function:
[100] Safe Option Reset
[107] Target Inverse
[108] Enable Master Offset
[109] Start Virtual Master
[110] Start Homing
[111] Activate Touch
[112] Relative Position
[113] Enable Reference
[114] Sync. to Pos. Mode
[115] Home Sensor
[116] Home Sensor Inv.
[117] Touch Sensor
[118] Touch Sensor Inv.
[119] Speed Mode
[231] Power Limit Mot.
[232] Power Limit Gen.
[233] Power Limit Both
5-19 Terminal 37 Safe Stop
Use this parameter to configure the Safe Torque Off functionality.
A warning message makes the frequency converter coast the
motor and enables the automatic restart. An alarm message
makes the frequency converter coast the motor and requires a
manual restart (via a fieldbus, Digital I/O, or by pressing [RESET]
on the LCP). When the VLT
®
PTC Thermistor Card MCB 112 is
mounted, configure the PTC options to get the full benefit from
the alarm handling.
Option:
Function:
[1]
Safe Stop Alarm Coasts the frequency converter when
Safe Torque Off is activated. Manual
reset from LCP, digital input, or
fieldbus.
[3]
Safe Stop
Warning
Coasts the frequency converter when
Safe Torque Off is activated (terminal
37 off). When the Safe Torque Off
circuit is re-established, the frequency
converter continues without manual
reset.
[4]
PTC 1 Alarm
Coasts the frequency converter when
Safe Torque Off is activated. Manual
reset from LCP, digital input, or
fieldbus.
[5]
PTC 1 Warning
Coasts the frequency converter when
Safe Torque Off is activated (terminal
37 off). When the Safe Torque Off
circuit is re-established, the frequency
converter continues without manual
reset, unless a digital input set to
[80]
PTC Card 1
is still enabled.
[6]
PTC 1 & Relay A This option is used when the VLT
®
PTC Thermistor Card MCB 112 gates
with a stop key through a safety relay
Parameter Descriptions
VLT
®
AutomationDrive FC 301/302
110
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02
3