Bit Hex
Dec
Alarm word
Alarm word 2
Warning word
Warning
word 2
Extended
status word
6
00000040
64
Torque limit (A12) Reserved
Torque limit (W12) Reserved
Feedback low
feedback <
parameter 4-56 Warning
Feedback Low
7
00000080
128
Motor th over
(A11)
Reserved
Motor th over
(W11)
Reserved
Output current high
current >
parameter 4-51 Warning
Current High
8
00000100
256
Motor ETR over
(A10)
Reserved
Motor ETR over
(W10)
Reserved
Output current low
current <
parameter 4-50 Warning
Current Low
9
00000200
512
Inverter overld.
(A9)
Discharge high
Inverter Overld
(W9)
Discharge
high
Output freq high
speed >
parameter 4-53 Warning
Speed High
10 00000400
1024
DC under volt (A8) Start failed
DC under volt
(W8)
Multi-motor
underload
Output freq low
speed <
parameter 4-52 Warning
Speed Low
11 00000800
2048
DC over volt (A7)
Speed limit
DC over volt (W7) Multi-motor
overload
Brake check OK
brake test NOT OK
12 00001000
4096
Short circuit (A16) External
interlock
DC voltage low
(W6)
Compressor
interlock
Braking max.
BrakePower > Brakepowerlimit
(2-12)
13 00002000
8192
Inrush fault (A33)
Illegal option
combi.
DC voltage high
(W5)
Mechanical
brake sliding
Braking
14 00004000
16384
Mains ph. loss (A4) No safety option Mains ph. loss
(W4)
Safe option
warning
Out of speed range
15 00008000
32768
AMA not OK
Reserved
No motor (W3)
Auto DC
braking
OVC active
16 00010000
65536
Live zero error
(A2)
Reserved
Live zero error
(W2)
AC brake
17 00020000
131072
Internal fault (A38) KTY error
10 V low (W1)
KTY warn
Password timelock
number of allowed password trials
exceeded - timelock active
18 00040000
262144
Brake overload
(A26)
Fans error
Brake overload
(W26)
Fans warn
Password protection
0-61 = ALL_NO_ACCESS OR
BUS_NO_ACCESS OR
BUS_READONLY
19 00080000
524288
U phase loss (A30) ECB error
Brake resistor
(W25)
ECB warn
Reference high
reference >
parameter 4-55 Warning
Reference High
20 00100000
1048576
V phase loss (A31) Hoist
mechanical
brake (A22)
Brake IGBT (W27)
Hoist
mechanical
brake (W22)
Reference low
reference <
parameter 4-54 Warning
Reference Low
21 00200000
2097152
W phase Loss
(A32)
Reserved
Speed limit (W49) Reserved
Local reference
reference site = REMOTE -> auto on
pressed & active
22 00400000
4194304
Fieldbus fault
(A34)
Reserved
Fieldbus fault
(W34)
Reserved
Protection mode notification
23 00800000
8388608
24 V supply low
(A47)
Reserved
24 V supply Low
(W47)
Reserved
Unused
24 01000000 16777216 Mains failure (A36) Reserved
Mains failure
(W36)
Reserved
Unused
25 02000000 33554432 1.8 V supply low
(A48)
Current limit
(A59)
Current limit
(W59)
Power Limit
Motor
Unused
Troubleshooting
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
329
6
6
Summary of Contents for VLT AutomationDrive FC 302