5.2.17 17-** Position Feedback
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
17-1* Inc. Enc. Interface
17-10 Signal Type
[1] RS422 (5V TTL)
All set-ups
FALSE
-
Uint8
17-11 Resolution (PPR)
1024 N/A
All set-ups
FALSE
0
Uint16
17-2* Abs. Enc. Interface
17-20 Protocol Selection
[0] None
All set-ups
FALSE
-
Uint8
17-21 Resolution (Positions/Rev)
ExpressionLimit
All set-ups
FALSE
0
Uint32
17-22 Multiturn Revolutions
1 N/A
All set-ups
FALSE
0
Uint32
17-24 SSI Data Length
13 N/A
All set-ups
FALSE
0
Uint8
17-25 Clock Rate
260 kHz
All set-ups
FALSE
3
Uint16
17-26 SSI Data Format
[0] Gray code
All set-ups
FALSE
-
Uint8
17-34 HIPERFACE Baudrate
[4] 9600
All set-ups
FALSE
-
Uint8
17-5* Resolver Interface
17-50 Poles
2 N/A
1 set-up
FALSE
0
Uint8
17-51 Input Voltage
7 V
1 set-up
FALSE
-1
Uint8
17-52 Input Frequency
10 kHz
1 set-up
FALSE
2
Uint8
17-53 Transformation Ratio
0.5 N/A
1 set-up
FALSE
-1
Uint8
17-56 Encoder Sim. Resolution
[0] Disabled
1 set-up
FALSE
-
Uint8
17-59 Resolver Interface
[0] Disabled
2 set-ups
FALSE
-
Uint8
17-6* Monitoring and App.
17-60 Feedback Direction
[0] Clockwise
All set-ups
FALSE
-
Uint8
17-61 Feedback Signal Monitoring
[1] Warning
All set-ups
TRUE
-
Uint8
17-7* Position Scaling
17-70 Position Unit
[0] pu
All set-ups
TRUE
-
Uint8
17-71 Position Unit Scale
0 N/A
All set-ups
FALSE
0
Int8
17-72 Position Unit Numerator
1024 N/A
All set-ups
FALSE
0
Int32
17-73 Position Unit Denominator
1 N/A
All set-ups
FALSE
0
Int32
17-74 Position Offset
0 N/A
All set-ups
FALSE
0
Int32
5.2.18 18-** Data Readouts 2
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
18-0* Maintenance Log
18-00 Maintenance Log: Item
0 N/A
All set-ups
x
FALSE
0
Uint8
18-01 Maintenance Log: Action
0 N/A
All set-ups
x
FALSE
0
Uint8
18-02 Maintenance Log: Time
0 s
All set-ups
x
FALSE
0
Uint32
18-03 Maintenance Log: Date and Time
ExpressionLimit
All set-ups
x
FALSE
0
TimeO
fDay
18-2* Motor Readouts
18-27 Safe Opt. Est. Speed
0 RPM
All set-ups
TRUE
67
Int32
18-28 Safe Opt. Meas. Speed
0 RPM
All set-ups
TRUE
67
Int32
18-29 Safe Opt. Speed Error
0 RPM
All set-ups
TRUE
67
Int32
18-3* Analog Readouts
18-36 Analog Input X48/2 [mA]
0 N/A
All set-ups
TRUE
-3
Int32
18-37 Temp. Input X48/4
0 N/A
All set-ups
TRUE
0
Int16
18-38 Temp. Input X48/7
0 N/A
All set-ups
TRUE
0
Int16
18-39 Temp. Input X48/10
0 N/A
All set-ups
TRUE
0
Int16
18-4* PGIO Data Readouts
18-43 Analog Out X49/7
0 N/A
All set-ups
FALSE
-3
Int16
Parameter Lists
VLT
®
AutomationDrive FC 301/302
282
Danfoss A/S © 10/2018 All rights reserved.