Parameter 13-42 Logic Rule
Boolean 2
[1]
[2] Running –
Parameter 13-41 Logic Rule
Operator 1
[1]
[1] AND
–
Parameter 13-15 RS-FF Operand
S
[0]
[26] Logic
rule 0
Output from
parameter 13-41 Log
ic Rule Operator 1
[0].
Parameter 13-16 RS-FF Operand
R
[0]
[27] Logic
rule 1
Output from
parameter 13-41 Log
ic Rule Operator 1
[1].
Parameter 13-51 SL Controller
Event
[0]
[94] RS
Flipflop 0
Output from
parameter 13-15 RS-
FF Operand S
and
parameter 13-16 RS-
FF Operand R
.
Parameter 13-52 SL Controller
Action
[0]
[22] Run
–
Parameter 13-51 SL Controller
Event
[1]
[27] Logic
rule 1
–
Parameter 13-52 SL Controller
Action
[1]
[24] Stop
–
Table 3.26 Operators
13-15 RS-FF Operand S
Option:
Function:
[0]
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
13-15 RS-FF Operand S
Option:
Function:
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Time-out 0
[31]
SL Time-out 1
[32]
SL Time-out 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
Ok key
[OK] is pressed. Only available on
the graphical LCP.
[44]
Reset key
[Reset] is pressed. Only available on
the graphical LCP.
[45]
Left key
[
◄
] is pressed. Only available on the
graphical LCP.
[46]
Right key
[
►
] is pressed. Only available on the
graphical LCP.
[47]
Up key
[
▲
] is pressed. Only available on
the graphical LCP.
[48]
Down key
[
▼
] is pressed. Only available on
the graphical LCP.
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
SL Time-out 3
[71]
SL Time-out 4
[72]
SL Time-out 5
[73]
SL Time-out 6
[74]
SL Time-out 7
[75]
Start command given
[76]
Digital input x30/2
[77]
Digital input x30/3
[78]
Digital input x30/4
[79]
Digital input x46/1
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
Parameter Descriptions
VLT
®
AutomationDrive FC 301/302
174
Danfoss A/S © 10/2018 All rights reserved.
MG33MP02
3
3
Summary of Contents for VLT AutomationDrive FC 302
Page 2: ......