
16-10 Power [kW]
0 kW
All set-ups
FALSE
1
Int32
16-11 Power [hp]
0 hp
All set-ups
FALSE
-2
Int32
16-12 Motor Voltage
0 V
All set-ups
FALSE
-1
Uint16
16-13 Frequency
0 Hz
All set-ups
FALSE
-1
Uint16
16-14 Motor current
0 A
All set-ups
FALSE
-2
Int32
16-15 Frequency [%]
0 %
All set-ups
FALSE
-2
N2
16-16 Torque [Nm]
0 Nm
All set-ups
FALSE
-1
Int16
16-17 Speed [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-18 Motor Thermal
0 %
All set-ups
FALSE
0
Uint8
16-19 Thermistor Sensor Temperature
0 °C
All set-ups
FALSE
100
Int16
16-20 Motor Angle
0 N/A
All set-ups
TRUE
0
Uint16
16-21 Torque [%] High Res.
0 %
All set-ups
FALSE
-1
Int16
16-22 Torque [%]
0 %
All set-ups
FALSE
0
Int16
16-23 Motor Shaft Power [kW]
0 kW
All set-ups
TRUE
1
Int32
16-24 Calibrated Stator Resistance
0.0000 Ohm
All set-ups
x
TRUE
-4
Uint32
16-25 Torque [Nm] High
0 Nm
All set-ups
FALSE
-1
Int32
16-28 Angle Error
0 °
All set-ups
FALSE
-2
Int16
16-3* Drive Status
16-30 DC Link Voltage
0 V
All set-ups
FALSE
0
Uint16
16-31 System Temp.
0 °C
All set-ups
x
TRUE
100
Int8
16-32 Brake Energy /s
0 kW
All set-ups
FALSE
0
Uint32
16-33 Brake Energy Average
0 kW
All set-ups
FALSE
0
Uint32
16-34 Heatsink Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-35 Inverter Thermal
0 %
All set-ups
FALSE
0
Uint8
16-36 Inv. Nom. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-37 Inv. Max. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-38 SL Controller State
0 N/A
All set-ups
FALSE
0
Uint8
16-39 Control Card Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-40 Logging Buffer Full
[0] No
All set-ups
TRUE
-
Uint8
16-41 Performance Measurements
0 N/A
All set-ups
TRUE
0
VisStr[
50]
16-42 Service Log Counter
0 N/A
All set-ups
TRUE
0
Uint8
16-43 Timed Actions Status
[0] Timed Actions Auto
All set-ups
TRUE
-
Uint8
16-44 Speed Error [RPM]
0 RPM
All set-ups
TRUE
67
Int32
16-45 Motor Phase U Current
0 A
All set-ups
TRUE
-2
Int32
16-46 Motor Phase V Current
0 A
All set-ups
TRUE
-2
Int32
16-47 Motor Phase W Current
0 A
All set-ups
TRUE
-2
Int32
16-48 Speed Ref. After Ramp [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-49 Current Fault Source
0 N/A
All set-ups
x
TRUE
0
Uint8
16-5* Ref. & Feedb.
16-50 External Reference
0 N/A
All set-ups
FALSE
-1
Int16
16-51 Pulse Reference
0 N/A
All set-ups
FALSE
-1
Int16
16-52 Feedback[Unit]
0 ReferenceFeedbackUnit
All set-ups
FALSE
-3
Int32
16-53 Digi Pot Reference
0 N/A
All set-ups
FALSE
-2
Int16
16-57 Feedback [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-6* Inputs & Outputs
16-60 Digital Input
0 N/A
All set-ups
FALSE
0
Uint16
16-61 Terminal 53 Switch Setting
[0] Current
All set-ups
FALSE
-
Uint8
16-62 Analog Input 53
0 N/A
All set-ups
FALSE
-3
Int32
16-63 Terminal 54 Switch Setting
[0] Current
All set-ups
FALSE
-
Uint8
16-64 Analog Input 54
0 N/A
All set-ups
FALSE
-3
Int32
16-65 Analog Output 42 [mA]
0 N/A
All set-ups
FALSE
-3
Int16
16-66 Digital Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-67 Freq. Input #29 [Hz]
0 N/A
All set-ups
x
FALSE
0
Int32
16-68 Freq. Input #33 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-69 Pulse Output #27 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
Parameter Lists
Programming Guide
MG33MP02
Danfoss A/S © 10/2018 All rights reserved.
311
5
5
Summary of Contents for VLT AutomationDrive FC 302
Page 2: ......