4-62 Bypass Speed To [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-63 Bypass Speed To [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-8* Power Limit
4-80 Power Limit Func. Motor Mode
[0] Disabled
All set-ups
x
TRUE
-
Uint8
4-81 Power Limit Func. Generator Mode
[0] Disabled
All set-ups
x
TRUE
-
Uint8
4-82 Power Limit Motor Mode
100.0 %
All set-ups
x
TRUE
-1
Uint16
4-83 Power Limit Generator Mode
100.0 %
All set-ups
x
TRUE
-1
Uint16
4-9* Directional Limits
4-90 Directional Limit Mode
[0] Disabled
All set-ups
TRUE
-
Uint8
4-91 Positive Speed Limit [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-92 Positive Speed Limit [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-93 Negative Speed Limit [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
4-94 Negative Speed Limit [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-95 Positive Torque limit
ExpressionLimit
All set-ups
TRUE
-1
Uint16
4-96 Negative Torque limit
ExpressionLimit
All set-ups
TRUE
-1
Uint16
5.2.6 5-** Digital In/Out
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
5-0* Digital I/O mode
5-00 Digital I/O Mode
[0] PNP
All set-ups
FALSE
-
Uint8
5-01 Terminal 27 Mode
[0] Input
All set-ups
TRUE
-
Uint8
5-02 Terminal 29 Mode
[0] Input
All set-ups
x
TRUE
-
Uint8
5-1* Digital Inputs
5-10 Terminal 18 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-11 Terminal 19 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-12 Terminal 27 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-13 Terminal 29 Digital Input
ExpressionLimit
All set-ups
x
TRUE
-
Uint8
5-14 Terminal 32 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-15 Terminal 33 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-16 Terminal X30/2 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-17 Terminal X30/3 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-18 Terminal X30/4 Digital Input
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-19 Terminal 37 Safe Stop
ExpressionLimit
1 set-up
TRUE
-
Uint8
5-20 Terminal X46/1 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-21 Terminal X46/3 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-22 Terminal X46/5 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-23 Terminal X46/7 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-24 Terminal X46/9 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-25 Terminal X46/11 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-26 Terminal X46/13 Digital Input
[0] No operation
All set-ups
TRUE
-
Uint8
5-3* Digital Outputs
5-30 Terminal 27 Digital Output
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-31 Terminal 29 Digital Output
ExpressionLimit
All set-ups
x
TRUE
-
Uint8
5-32 Term X30/6 Digi Out (MCB 101)
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-33 Term X30/7 Digi Out (MCB 101)
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-4* Relays
5-40 Function Relay
ExpressionLimit
All set-ups
TRUE
-
Uint8
5-41 On Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-42 Off Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-5* Pulse Input
5-50 Term. 29 Low Frequency
100 Hz
All set-ups
x
TRUE
0
Uint32
5-51 Term. 29 High Frequency
ExpressionLimit
All set-ups
x
TRUE
0
Uint32
5-52 Term. 29 Low Ref./Feedb. Value
0 ReferenceFeedbackUnit
All set-ups
x
TRUE
-3
Int32
Parameter Lists
Programming Guide
MG33MP02