E1200 HT 260-3
3BFunctional Description
23.04.07
00401010_41087
4-9
4.2.5
Cooling System
1
2
3
DIF00324
Figure 4-6:
Water Cooling with Stack Heat Exchanger
Description of items in figure 4-6:
1 stack heat exchanger
3 shut-off valves
2 main
cooler
An air-water-heat exchanger which is used as stack heat exchanger (4-6/1) is mounted
above each stack of the horizontal furnace. If a stack is equipped with a water-cooled
heating cassette, this stack heat exchanger is omitted.
Each stack is equipped with its own cooling cycle to reduce the thermal interference
between heating cassettes. Each cooling cycle can be switched on and of individually.
The water flow rates of the stack heat exchangers and of the main cooler (4-6/2) are
regulated individually. Flow rate monitors monitor the flow of cooling water. The shut-off
valves (4-6/3) are mounted on the upper front side of the horizontal furnace.
Summary of Contents for E1200 HT 260-3
Page 1: ...Operating Instructions for Horizontal Furnace Equipment E1200 HT 260 3 Version 1 0 1_41087 11 ...
Page 2: ...E1200 HT 260 3 23 04 07 00401010_41087 ...
Page 4: ...E1200 HT 260 3 Document Information 23 04 07 00401010_41087 ...
Page 16: ...E1200 HT 260 3 Index 23 04 07 00401010_41087 ...
Page 18: ...E1200 HT 260 3 List of Figures 23 04 07 00401010_41087 ...
Page 20: ...E1200 HT 260 3 List of Tables 23 04 07 00401010_41087 ...
Page 26: ...E1200 HT 260 3 0BOperating Instruction Remarks 23 04 07 1 6 00401010_41087 ...
Page 34: ...E1200 HT 260 3 1BIntroduction 23 04 07 2 8 00401010_41087 ...
Page 50: ...E1200 HT 260 3 2BSafety 23 04 07 3 16 00401010_41087 ...
Page 78: ...E1200 HT 260 3 4BTransport 23 04 07 5 4 00401010_41087 ...
Page 180: ...E1200 HT 260 3 8BMaintenance 23 04 07 9 76 00401010_41087 ...
Page 228: ...E1200 HT 260 3 10BSpare and Wearing Parts 23 04 07 11 2 00401010_41087 ...