9.3.6
Cell Controller Disturbances
The connection to the CESAR control computers is disturbed.
1. Check LED at the hub's remote data concentrator (position in gas cabinet/door).
One LED per connected channel must continuously light up. If the LED does not
shine continuously: wire breakage or network card damaged.
2. Reboot the computer if there is no connection. A damaged network card triggers a
fault message, refer to the CESAR control computer manual listed in chapter
12.3 Information on the Control System, page 12-2.