E1200 HT 260-3
9BPreventive Maintenance
23.04.07
00401010_41087
10-37
10.12.13
Checking the Synthesis Steam Generator
For a description of the work steps to check the synthesis steam generator see
Synthesis Steam Generator Manual in chapter 12.5 Information on the Gas System,
page 12-2.
1. Check the quartz glass parts for cracks and damage. Replace torn and damaged
quartz parts.
2. Check the thermocouples.
3. Check the ultraviolet sensor.
10.12.14
Checking the PECVD Vacuum System
WARNING - Noxious or irritating dust particles and/or gases!
The vacuum tubing can contain noxious or irritating dust particles and/or gases.
Always wear safety gloves during preventive maintenance work.
Always wear a respirator during preventive maintenance work.
Carry out the following tests:
—
check HF lances
—
check main, butterfly and softpump valve
—
check O-rings
—
check vacuum pump
Additionally, keep ready for the installation:
—
O-rings for back flange and tube closure
—
tube case
—
HF contact tips
—
main, butterfly and softpump valve
Summary of Contents for E1200 HT 260-3
Page 1: ...Operating Instructions for Horizontal Furnace Equipment E1200 HT 260 3 Version 1 0 1_41087 11 ...
Page 2: ...E1200 HT 260 3 23 04 07 00401010_41087 ...
Page 4: ...E1200 HT 260 3 Document Information 23 04 07 00401010_41087 ...
Page 16: ...E1200 HT 260 3 Index 23 04 07 00401010_41087 ...
Page 18: ...E1200 HT 260 3 List of Figures 23 04 07 00401010_41087 ...
Page 20: ...E1200 HT 260 3 List of Tables 23 04 07 00401010_41087 ...
Page 26: ...E1200 HT 260 3 0BOperating Instruction Remarks 23 04 07 1 6 00401010_41087 ...
Page 34: ...E1200 HT 260 3 1BIntroduction 23 04 07 2 8 00401010_41087 ...
Page 50: ...E1200 HT 260 3 2BSafety 23 04 07 3 16 00401010_41087 ...
Page 78: ...E1200 HT 260 3 4BTransport 23 04 07 5 4 00401010_41087 ...
Page 180: ...E1200 HT 260 3 8BMaintenance 23 04 07 9 76 00401010_41087 ...
Page 228: ...E1200 HT 260 3 10BSpare and Wearing Parts 23 04 07 11 2 00401010_41087 ...