E1200 HT 260-3
8BMaintenance
23.04.07
9-18
00401010_41087
ID No. Error message
text
Cause Troubleshooting
3294 error pH value
stack 2
see ID No. 3290 see ID No. 3290
3296
3297
overpressure
15 mbar/
25 mbar
stack 3
see ID No. 3288 see ID No. 3288
3298 error pH value
stack 3
see ID No. 3290 see ID No. 3290
3470
3471
3472
3473
3474
error heating
circuit zone:
- L stack1-3
- LM stack 1-3
- M stack 1-3
- GM stack1-3
- G stack 1-3
error in power
supply circuit or
control circuit
Check power supply circuit and control
circuit.