7.4.2
Shutting Down the Equipment
Proceed as follows before shutting down the equipment out of action:
—
Purge the gas lines for toxic and/or reactive gases and the process tubes with inert
gas, see chapter 9.10 Working on the Gas System, page 9-65.
—
Close all stop valves of the gas supply system.
—
Disconnect equipment from the electric mains.
—
Close the cooling water supply after all heating cassettes have cooled down (max.
temperature per heating cassette: 50 °C).
—
In case the storage place is not free of frost, purge the cooling circuits with
antifreeze.
7.5
Waste Disposal
The machine must be disposed of in accordance with the relevant recycling laws. A
disposal proof must be maintained for waste requiring special supervision.
Only disposal according to regulations protects man and environment.
6
6
valid for Germany, observe local regulations
Summary of Contents for E1200 HT 260-3
Page 1: ...Operating Instructions for Horizontal Furnace Equipment E1200 HT 260 3 Version 1 0 1_41087 11 ...
Page 2: ...E1200 HT 260 3 23 04 07 00401010_41087 ...
Page 4: ...E1200 HT 260 3 Document Information 23 04 07 00401010_41087 ...
Page 16: ...E1200 HT 260 3 Index 23 04 07 00401010_41087 ...
Page 18: ...E1200 HT 260 3 List of Figures 23 04 07 00401010_41087 ...
Page 20: ...E1200 HT 260 3 List of Tables 23 04 07 00401010_41087 ...
Page 26: ...E1200 HT 260 3 0BOperating Instruction Remarks 23 04 07 1 6 00401010_41087 ...
Page 34: ...E1200 HT 260 3 1BIntroduction 23 04 07 2 8 00401010_41087 ...
Page 50: ...E1200 HT 260 3 2BSafety 23 04 07 3 16 00401010_41087 ...
Page 78: ...E1200 HT 260 3 4BTransport 23 04 07 5 4 00401010_41087 ...
Page 180: ...E1200 HT 260 3 8BMaintenance 23 04 07 9 76 00401010_41087 ...
Page 228: ...E1200 HT 260 3 10BSpare and Wearing Parts 23 04 07 11 2 00401010_41087 ...