ID 1000 – 3000 Error Messages CMI
Only stated ID No. are used.
ID No.
Error message text
Cause
Troubleshooting
1351 PLC not in "Running"
status.
PLC control system
stopped.
Terminate CMI application,
start PLC, start CMI.
1353 EWH: The external
wafer handler is no
longer active. No
update of the life
guarding information!
No response from
external wafer handler.
Check external wafer
handler status.
1354 EWH: OPC Server of
external wafer handler
terminated.
see error text
Terminate CMI application,
restart CMI.
1355 Wafer handler in
ColdZone collision
range. Move wafer
handler out of danger
zone in manual.
see error text
see error text
1356 Time sync with cell
controller failed. Clock
drift too large. Use
AlarmAcknowledge for
time sync.
see error text
see error text
1357 Time sync with cell
controller failed. Time
service not executed
on timesrv.
see error text
Install centrotherm time
service on timesrv
computer and start.
Summary of Contents for E1200 HT 260-3
Page 1: ...Operating Instructions for Horizontal Furnace Equipment E1200 HT 260 3 Version 1 0 1_41087 11 ...
Page 2: ...E1200 HT 260 3 23 04 07 00401010_41087 ...
Page 4: ...E1200 HT 260 3 Document Information 23 04 07 00401010_41087 ...
Page 16: ...E1200 HT 260 3 Index 23 04 07 00401010_41087 ...
Page 18: ...E1200 HT 260 3 List of Figures 23 04 07 00401010_41087 ...
Page 20: ...E1200 HT 260 3 List of Tables 23 04 07 00401010_41087 ...
Page 26: ...E1200 HT 260 3 0BOperating Instruction Remarks 23 04 07 1 6 00401010_41087 ...
Page 34: ...E1200 HT 260 3 1BIntroduction 23 04 07 2 8 00401010_41087 ...
Page 50: ...E1200 HT 260 3 2BSafety 23 04 07 3 16 00401010_41087 ...
Page 78: ...E1200 HT 260 3 4BTransport 23 04 07 5 4 00401010_41087 ...
Page 180: ...E1200 HT 260 3 8BMaintenance 23 04 07 9 76 00401010_41087 ...
Page 228: ...E1200 HT 260 3 10BSpare and Wearing Parts 23 04 07 11 2 00401010_41087 ...