background image

 

1120 North Main Street • Elkhart, IN 46514 

USA : 

800-546-8759  

Canada & USA : 

800-825-4328 

Internet:

 http://www.atwoodmobile.com 

 

 

Literature number 30093 

hydro flame

™ 

Furnace Models 

SERIES 7900-II, 8012-II,  

SERIES 8500-IV 

SERIES 8900-III 

 

Series User’s Information Manual

 

English, Français (ET Canada) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Should you require further information, contact your dealer or nearest 
Atwood Mobile Products Service Center. 
Follow this instruction to insure safe operation of the furnace.  
This book contains instructions covering the operation and 
maintenance of your furnace. Keep with unit at all times. 

 
 
 
 
 

“FOR COMPLETE INSTALLATION INSTRUCTION REFER TO THE 
INSTALLATION OWNER’S MANUAL” 
 

 

 

INDEX 

2

 

3

 

3

 

4

 

ANNUAL PREVENTATIVE MAINTENANCE INSPECTION

6

 

6

 

6

 

6

 

7

 

 

FOR YOUR SAFETY READ ALL INFORMATION 

BEFORE OPERATING FURNACE 

 
SAFETY SYMBOLS 

 

 

   

 

 

 

 

 

 

 

 

 

 

 
 
 
BEFORE OPERATING FURNACE

, smell all around appliance area for 

gas and check fitting with a soapy water solution. Be sure to smell next 
to floor because some gas is heavier than air and will settle near floor. 
 
This  appliance  does  not  have  a  pilot.  It  is  equipped  with  an  ignition 
device  which  automatically  lights  the  burner.  DO  NOT  try  to  light  the 
burner by hand. 
 
Use only your hand to turn a gas control valve. Never use tools. If the 
valve will not turn by hand, don’t try to repair it.  Call a qualified Service 
Technician.  Forcing  or  attempting  to  repair  may  result  in  a  fire  or 
explosion. 
 
Do  not  use  the  appliance  if  any  part  has  been  under  water, 
immediately call a qualified Service Technician to inspect the appliance 
and  to  replace  any  part  of  control  system  and  any  gas  control  which 
has been under water. 
 

 WARNING 

Improper installation, adjustment, alteration, service or 
maintenance can cause property damage, personal injury or 
loss of life. Refer to the installation instructions and/or 
owners manual provided with this appliance. 

 CAUTION 

PERSONAL INJURY 

 

DO NOT touch exterior exhaust grills, when furnace is 
operating. 

 

Supervise young children in the same room as the 
furnace. 

  

WARNING 

POSSIBLE INJURY OR DEATH 

 

Your  furnace  should  be  inspected  by  a  qualified  service  agency 
yearly before turning the furnace on. Particular attention should be 
given to the following items. 

 WARNING 

Installation of this appliance must be made in accordance 
with the written instructions provided in this manual. No 
agent, representative or employee of Atwood or other 
person has the authority to change, modify or waive any 
provision of the instructions contained in this manual. 

 

 WARNING 

FIRE OR EXPLOSION 

 

If information in this manual is not followed exactly, a fire or 
explosion  may  result  causing  property  damage,  personal 
injury or loss of life. 

 WARNING 

FIRE OR EXPLOSION 

 

Be sure the furnace and all ignition systems are “OFF” 
during any type of refueling and while vehicle is in motion or 
being towed. 

  CAUTION 

Avoid possible injury and/or 

property damage 

SAFETY ALERT SYMBOLS 

Safety symbols alerting you to potential personal safety hazards. 

Obey all safety messages following these symbols. 

  WARNING 

Avoid possible 

injury or death 

LOCATION AND PHONE NUMBERS QUALIFIED SERVICE CENTERS 

  Website http://www.atwoodmobile.com 

  Call 866-869-31181 for Atwood Service Center List 

TO THE INSTALLER:  

LEAVE THIS MANUAL WITH THE 
APPLIANCE. 

TO THE CONSUMER:  

RETAIN THIS MANUAL FOR 
FUTURE REFERENCE. 

 

 

 

 

Effective 10/10 

OPERATING INSTRUCTIONS

. . . . . . . . . . . . . . . . . . . . . . . .

SERVICING

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

VALVE CONVERSION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE AND CLEANING

. . . . . . . . . . . . . . . . . . . . .

GAS CONVERSION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

 

ORIFICE REPLACEMENT

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

 

5

 

FURNACE EXTENDED SERVICE CONTRACT

 . . . . . . . . . .

.

EXTENDED SERVICE ORDER FORM

 . . . . . . . . . . . . . . . . . .

EXCLUSIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WARRANTY

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

 

LIMITATIONS

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

TERM AND PROVISIONS:

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for hydro flame 7900-II series

Page 1: ...ation service or maintenance can cause property damage personal injury or loss of life Refer to the installation instructions and or owners manual provided with this appliance CAUTION PERSONAL INJURY DO NOT touch exterior exhaust grills when furnace is operating Supervise young children in the same room as the furnace WARNING POSSIBLE INJURY OR DEATH Your furnace should be inspected by a qualified...

Page 2: ...r use gasoline or other flammable vapors and or liquids in the vicinity of this or any other appliance DO NOT use the furnace cabinet area as a storage compartment DO NOT block furnace outlet registers or return air grills Keep all insulating material away from furnaces HOW TO TURN OFF ELECTRICAL POWER 1 Set the thermostat at the lowest setting 2 Open furnace exterior door and turn OFF electrical ...

Page 3: ... products of combustion being vented into the room or occupied areas In any installation in which the vent of the appliance can be covered due to the construction of the RV or some special feature of the RV such as slide out pop up etc Always insure that the appliance cannot be operated by setting the thermostat to the positive OFF position and shutting off all electrical and gas supply to the app...

Page 4: ...upstream of gas connections for checking gas pressure GAS TYPE BTU HR LINE PRESSURE REG PLUG SETTING DRILL SIZE Propane LP 40 000 11 WC 10 5 WC 49P Natural Nat 40 000 7 WC 3 5 WC 30N Propane LP 35 000 11 WC 10 5 WC 51P Natural Nat 35 000 7 WC 3 5 WC 32N WC Water Column VALVE CONVERSION 1 See drawing to check exposed section on side of adjustment reg plug to determine whether it is set for natural ...

Page 5: ...he discretion of the manufacturer This warranty is void if the product has been damaged by accident unreasonable use neglect tampering or other cause not arising from defects in material workmanship This warranty extends to the original owner of the product only and is subject to the following conditions 1 For two years from the date of purchase Atwood will repair or replace any part defective in ...

Page 6: ...or warranty service rendered on a direct basis only 4 Repairs replacement parts and or furnace replacement authorized by Atwood shall be subject to the remainder of the warranty of any of the aforesaid two year period EXCLUSIONS SPECIFICALLY EXCLUDED FROM THE WARRANTIES 1 Incidental or consequential damages 2 Damage caused by shipment 3 Damage resulting from improper installation misuse neglect ac...

Page 7: ...7 EXTENDED SERVICE ORDER FORM ...

Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK CETTE PAGE EST INTENTIONNELLEMENT VIDE ...

Page 9: ...THIS PAGE INTENTIONALLY LEFT BLANK CETTE PAGE EST INTENTIONNELLEMENT VIDE ...

Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK CETTE PAGE EST INTENTIONNELLEMENT VIDE ...

Page 11: ... service qualifié pour inspecter l appareil et remplacer toute pièce du système de commande et toute commande de gaz qui a été en contact avec de l eau AVERTISSEMENT INCENDIE OU EXPLOSION Assurez vous que la fournaise et tous les systèmes d allumage sont sur OFF ARRÊT durant tout processus de ravitaillement en carburant et pendant que le véhicule est en mouvement ou est remorqué AVERTISSEMENT BLES...

Page 12: ...PAS ou n utilisez pas de l essence ou tout autre liquide ou vapeur inflammable à proximité de cette fournaise ou tout autre appareil N UTILISEZ PAS la zone de l armoire de la fournaise comme compartiment d entreposage NE BLOQUEZ PAS les registres de sortie de la fournaise ou les grilles d air repris Gardez tout le matériel d isolation loin des fournaises COMMENT COUPER LE COURANT ÉLECTRIQUE 1 Régl...

Page 13: ... attention à la ventilation de votre fournaise Pour votre sécurité ne raccordez pas l évent de la fournaise à l intérieur de pièces ajoutées du grillage de la véranda ou sur les terrasses Ceci entraînerait la ventilation des produits de combustion à l intérieur de la pièce ou les aires habitables Dans toute installation dans laquelle l évent de l appareil peut être couvert en raison de la construc...

Page 14: ...f frein filet sur les fils d orifice lors de l installation d un nouvel orifice Une prise NPT de 1 8 est fournie en amont des connexions de gaz pour vérifier la pression de gaz TYPE DE GAZ BTU HR PRESSION DE LIGNE RÉGLAGE DU BOUCHON REG GRANDEUR DE FORET Propane LP 40 000 11 WC 10 5 CE 49P Naturel Nat 40 000 7 WC 3 5 CE 30N Propane LP 35 000 11 WC 10 5 CE 51P Naturel Nat 35 000 7 WC 3 5 CE 32N CE ...

Page 15: ... ou usées GARANTIE Atwood Mobile Products GARANTIE LIMITÉE DE LA FOURNAISE hydro flammeMC Atwood Mobile Products garantit au propriétaire original et sous réserve des conditions mentionnées ci dessous que le produit hydro flammeMC sera exempt de défauts de fabrication et de matériau pendant une période de deux ans suivant la date d achat originale La responsabilité d Atwood en vertu de la présente...

Page 16: ...rvice de garantie rendu sur une base directe seulement 4 Les réparations les pièces de rechange et ou le remplacement de la fournaise autorisé par Atwood seront assujettis à la période restante de la garantie de toute période de deux ans susvisée EXCLUSIONS SONT SPÉCIFIQUEMENT EXCLUS DES GARANTIES 1 Les dommages indirects ou consécutifs 2 Les dommages causés par une expédition 3 Les dommages surve...

Reviews: