System Renumbering
3–18
Common Administrative Procedures
Procedure: Block Renumbering
Console Display/Instructions
Additional Information
PC
1
Select the System Renumber menu.
System Programming:
>
Make a selection
System
Extensions
_
SysRenumber
Options
Operator
Tables
LinesTrunks
AuxEquip
Exit
NightSrvce
2
2
Select Block renumbering.
System Renumber:
If you get the System Busy message, wait
Make a selection
for an idle condition or exit system
Default Numbering
programming and try again later.
Single
_
Block
Exit
3
3
Select the type of group to renumber.
Block Renumber:
Make a selection
_
Lines
_
Extensions
_
Adjuncts
Select
Lines
Lines
,
1
Extensions
Extensions
, or
2
Exit
Adjuncts
Adjuncts
.
3
4
Enter the currently assigned number for the first member of the group.
Number ****:
**** = option name selected in Step 3
Enter starting ****
Backspace
Exit
Enter
SP:
“Entering an Extension”
Û
5
Save your entry.
Select
Enter
.
0
Summary of Contents for MERLIN LEGEND Release 3.1
Page 372: ...Memory Card 3 236 Common Administrative Procedures...
Page 572: ...Telephones 4 200 Programming Procedures...
Page 715: ...Memory Card Programming Procedures 4 343...
Page 749: ...Feature Quick Reference 5 34 Centralized Telephone Programming...
Page 773: ...Customer Support Information B 2 System Programming...
Page 798: ...Button Diagrams E 6 System Programming...
Page 800: ...Sample Reports F 2 System Programming Continued on next page...