BRI Facilities
Programming Procedures
4–189
Table 4–4. Timers
Timer/Counter Purpose
Factory Setting Valid Range
Increments
T200 Timer
maximum response time 1000 ms
500 to 5000 ms 500 ms
T203 Timer
maximum time
33 seconds
10 to 255 sec
1 sec
T303 Timer
Set up timeout
4 seconds
2 to 10 sec
1 sec
T305 Timer
Disconnect timeout
30 seconds
2 to 60 sec
1 sec
T308 Timer
Release timeout
4 seconds
2 to 10 sec
1 sec
Procedure: Timers
Console Display/Instructions
Additional Information
PC
1
Select the Lines and Trunks menu.
System Programming:
>
Make a selection
System
Extensions
SysRenumber
Options
Operator
Tables
_
LinesTrunks
AuxEquip
Exit
NightSrvce
4
2
Go to the second screen of the Lines and Trunks menu.
Lines and Trunks:
>
Make a selection
LS/GS/DS1
PRI
TIE Lines
Copy
TT/LS Disc
RemoteAccss
DID
Pools
Exit
Toll Type
Press
More
.
u
3
Select BRI.
Lines and Trunks:
>
Make a selection
HoldDiscnct
LS-ID Delay
PrncipalUsr
ClockSync
QCC Prior
BRI
_
QCC Oper
Exit
8
Summary of Contents for MERLIN LEGEND Release 3.1
Page 372: ...Memory Card 3 236 Common Administrative Procedures...
Page 572: ...Telephones 4 200 Programming Procedures...
Page 715: ...Memory Card Programming Procedures 4 343...
Page 749: ...Feature Quick Reference 5 34 Centralized Telephone Programming...
Page 773: ...Customer Support Information B 2 System Programming...
Page 798: ...Button Diagrams E 6 System Programming...
Page 800: ...Sample Reports F 2 System Programming Continued on next page...