CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-45
d. STEP 1–9
Set the welding current up (-down) ratio
(
RATIO
) for each
STEP
.
e. COUNT 1–9
Set the number of welds (
COUNT
) for each
STEP
.
The sequence will proceed to the next
STEP
following completion of the specified number of
welds.
f. RP2
Set the number of repetition (
COUNT
) for
STEP2
.
The sequence will proceed to the next
STEP3
following completion of the specified number
of welds.
STEP2
is repeated the set number of times, and the sequence will proceed to the
next
STEP3
.
g. TD 1–9
Set the chip dress for each
STEP
. When TD is set, X is displayed.
For
STEP
with the tip dress setting, the tip dress error occurs following completion of the
specified number of welds.
h. CAP CHANGE
Set the cap change (
COUNT
) for
STEP9
.
The cap change error occurs following completion of the specified number of welds for
STEP9
.
When the number of welds is set in
CAP CHANGE
, prior notice for cap change will be given
before the cap change error occurs.
Specify the number of welds to give prior notice how many numbers before the number of
welds (
STEP9 COUNT
) that the cap change error occurs.
For example, when
STEP9 COUNT
is 1000 (the number of welds that the cap change error
occurs) and
CAP CHANGE
is 10, prior notice is given when the stepper count is 990.
TD setting