CHAPTER 5: MAINTENANCE
IS-2200CA/4500CA INVERTER POWER SUPPLY
5-6
990-412
NOTES:
•
When the next start signal is received while the monitor error is displayed on the Pendant, the
CAUTION
signal is turned OFF and the previous screen is displayed. At this time, the data is
transferred to the Pendant from the Power Supply. The start signal is not received while the data is
transferred. (Ta: 40ms max. in the figure above.) When the monitor error is displayed, input the start
signal more than (Ta) time.
•
When the sequence ends, the
END
signal is output after
HOLD
. To make the cycle time faster, lower
the output time of END signal. (Can be set in 10-ms increment. The minimum value is 10ms.)
•
When the
MONITOR
screen is displayed, the monitor data is transferred to the Pendant simultaneously
with the
END
signal output (transmission time Tb1). The monitor data is not transferred when the
screen other than
MONITOR
screen is displayed.
The next Start signal is not received while the monitor data is transferred. Also, on every screen, the
data is transferred to the Pendant from the Power Supply to display the monitor error when the monitor
data is beyond/below the upper/lower limit (data communication time Tb2). The data communication
time at end “Tb” is shown in the table below.
MONITOR ERROR
OCCURS
MONITOR ERROR
DOES NOT OCCUR
MONITOR screen
Tb1: 164ms max.
Tb1+Tb2+α:
280 (438) ms max.
Screens other than
MONITOR screen
0ms
Tb2:
113 (144) ms max.
*
Time in ( ) is the time with RS-232C communication.
•
When the RS-232C external communication function is set to the single-directional communication
mode (
MODE SELECT
Screen), the monitor data is transferred to the host computer after the
completion of welding (transmission time
Tc1
).
Also, when the monitored value is outside the upper/lower limit on the
MONITOR SET
screen, the
monitor error code is transferred to the host computer (transmission time
Tc2
). The Start signal is not
received while during transmitting.
To make start time faster, set the external communication function to OFF. Shown below is the data
transmission time
Tc1
and
Tc2
when the communication speed is 9600 bps. When the communication
speed is 19200bps or 38400bps, the transmission time will be short.
•
Data transmission time when the communication speed is 9600 bps
Tc1
132ms max.
Tc2
42ms max.