APPENDIX C: SYSTEM TIMING
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
C-7
Pulsation
Operation is repeated in
WELD
and
INT
set times.
2ND STAGE
SQD
SQZ
WELD1
INT1
COOL1
WELD2
INT2
COOL2
WELD3
INT3
HOLD
SOL1/SOL2
HEAT1
HEAT1
HEAT2
HEAT2
PULSAT ION1
PULSAT ION2
PULSAT ION3
HEAT3
HEAT3
(Note 1 )
(Note 2 )
(Note 3 )
We ld ing current
OUT I
OUT I I
(Note 1) Repeat operation times set for PULSATION1 in WELD1 and INT1 set times.
When PULSATION is set to 3, WELD to INT are repeated 3 times as follows;
SQZ
→
WELD1
→
INT1
→
WELD1
→
INT1
→
WELD1
→
INT1
→
WELD2
(Note 2) Repeat operation times set for PULSATION2 in WELD2 and INT2 set times.
(Note 3) Repeat operation times set for PULSATION3 in WELD3 and INT3 set times.