CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
990-412
3-35
GOOD:
Count-up is done if the judgment is
GOOD
in current-supplied monitoring.
In case of errors other than the counter error, count-up is not done. Also, when the welding is
interrupted, count-up is not done.
Judgment in Monitor
Counting Manner
GOOD (normal)
Count-up.
Upper/lower
limit monitor
CAUTION
No Count-up.
ERROR
Error/Interrupt
WORK:
Count-up is not done if the judgment is
ERROR
in current-supplied monitoring.
Judgment in Monitor
Counting Manner
GOOD (normal)
WELD Counter counts-up.
WORK Counter counts-up (increment of+1)
when WELD Count reached the set value.
Upper/lower
limit monitor
CAUTION
ERROR
WELD Counter does not count-up.
WELD Counter is reset to 0 (zero) when
NG is reset. WORK Counter does not
count-up.
Error
Interrupt
WELD Counter does not count-up.
Since an error does not occur, the error reset
is not received.
q. SCAN MODE
Cannot be used. Select OFF.
r. COMM CONTROL
Selects a communication function.
OFF
No communication
→
One-way communication
↔
Both-way communication