![Amada S-2200CA Operation Manual Download Page 194](http://html1.mh-extra.com/html/amada/s-2200ca/s-2200ca_operation-manual_2915805194.webp)
APPENDIX E: COMMUNICATIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
E-6
990-412
2) Error Data
IS-2200CA/4500CA Data strings:
!01 000 :E03, 04, 12, 15, 17, 19, 22, 26 [CR][LF]
A B
C D E F G H I J
A
Device No.
Fixed to 2 digits (01 to 31)
B
Schedule No.
Fixed to 3 digits (001 to 255)
C*
1
Error code 1
Fixed to 3 digits (E01 to E39)
D*
1
Error code 2
Fixed to 2 digits (01 to 39)
E*
1
Error code 3
Fixed to 2 digits (01 to 39)
F*
1
Error code 4
Fixed to 2 digits (01 to 39)
G*
1
Error code 5
Fixed to 2 digits (01 to 39)
H*
1
Error code 6
Fixed to 2 digits (01 to 39)
I*
1
Error code 7
Fixed to 2 digits (01 to 39)
J*
1
Error code 8
Fixed to 2 digits (01 to 39)
*1 The maximum number of Error Codes is 8. In the case of only one error code, errors
D through J are omitted.
For Error Codes, see
Chapter 5: Maintenance, Section I: Troubleshooting
*2 Error codes are transmitted when errors are detected.
For the monitored value error and counter error, however, the error is transmitted after
the monitored data is transmitted.