
CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
3-42
990-412
WELD STOP OFF T IME
Set va lue
We ld ing stop
s igna l input
When the welding stop signal is input after WELD STOP OFF TIME
The welding is stopped when the welding stop signal is input.
11.
STEPPER COUNT Screen
The Power Supply can change the level of the welding current depending on the welding conditions.
The function to increase the welding current is called the “step-up” function, and that to decrease
the welding current is called the “step-down” function. Set the step-up or step-down timing based
on the number of welds. When the set number of welds is complete, the step end signal (
STEP END
)
is output.
a. START ON STEP #
The counting of welds starts from the
STEP
set here.
If, for example, you select
START ON STEP #3
as shown above, welds will be counted from
the first weld in
STEP3
, even if welding for the first time. Further, the welding current will be
increased (or reduced) by the extent you have set this value for
STEP3
.
Set the desired
STEP
No. 1–9 for
VALVE1
and
VALVE2, or SOL 1 – 4,
respectively,
depending on the valve mode selection.
(d) (e) (f) (g) (d) (e) (g)
(c)
(b)
(d)
(e)
(g)
(h)
(a)
(d)
(e)
(g)
Summary of Contents for S-2200CA
Page 1: ...990 412 REV G INVERTER POWER SUPPLY IS 2200CA 4500CA OPERATION MANUAL...
Page 20: ......
Page 31: ...CHAPTER 1 SYSTEM DESCRIPTION IS 2200CA 4500CA INVERTER POWER SUPPLY 990 412 1 11...
Page 38: ......
Page 114: ......
Page 136: ......
Page 168: ......