CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
3-32
990-412
m. VALVE MODE
Select the output method (1 VALVE or 2 VALVE) of the solenoid valve signal.
When
1 VALVE
is selected
When the 1ST STAGE signal is input, the valve signal (SOL1 - 4) with the selected schedule
number is output and the sequence waits for the 2ND STAGE signal input. Next, when the
2ND STAGE signal is input, the welding sequence with the selected schedule number starts.
After the welding sequence starts, the valve signal is output until the sequence ends even if the
1ST STAGE signal is turned OFF.
T: DELAY START SET (1 to 20ms)
TW: 2ND STAGE signal input wait time (uncertain)
SQD SQZ
U
U
D
D
WE1
WE2
U
D
HO
CO1
CO2
WE3
TW
T
32 ,64 ,128 ,P)
(1 ,2 ,4 ,8 ,16
T
1ST STAGE
2ND STAGE
Va lve output (SOL1 or SOL2 )
We ld ing sequence
Schedu le se lect ion
When the 2ND STAGE signal is input, the valve signal (SOL1 or SOL2) with the selected
schedule number is output. After the welding sequence starts, the valve signal is output until
the sequence ends even if the 2ND STAGE is turned OFF.
2ND STAGE
32 ,64 ,128 ,P )
SQD SQZ
U
U
D
D
WE1
WE2
U
D
HO
CO1
CO2
WE3
T
(1 ,2 ,4 ,8 ,16
Va lve output (SOL1 or SOL2 )
We ld ing sequence
Schedu le se lect ion
When
2 VALVE
is selected
2 valve signals (VALVE 1, 2) are output in a sequence.
When VALVE 1 is used, the weld force position can be adjusted by the 1ST STAGE signal
output timing of VALVE 2 to the start of SQZ.
After the welding sequence starts, the valve signal is output until the sequence ends even if the
1ST STAGE signal is turned OFF. When VALVE MODE is set to 2 VALVE, the following
functions become disabled.
1-4
1-4