![Amada S-2200CA Operation Manual Download Page 108](http://html1.mh-extra.com/html/amada/s-2200ca/s-2200ca_operation-manual_2915805108.webp)
CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-2200CA/4500CA INVERTER POWER SUPPLY
3-54
990-412
l. CHAINING
Used for the chaining function.
The welding is performed with SCHEDULEs with the chaining setting in order while the start
signal (1ST and 2ND) is input.
All values of the chained schedules must be entered, especially the turns ratio, to ensure proper
weld output.
For example, when CHAINING for SCHEDULE 1, 2, 5, and 6 are ON, the welding is performed
sequentially in order of SCHEDULE 1
→
SCHEDULE 2
→
SCHEDULE 5
→
SCHEDULE 6
by the start signal (1ST and 2ND) input.
m. SUCCESSIVE
Used for the successive function.
The welding is performed with SCHEDULEs with the successive setting in order each time the
start signal (1ST and 2ND) is input.
For example, when SUCCESSIVE for SCHEDULE 1, 2, 5, and 6 are ON, the welding is
performed singly in order of SCHEDULE 1
→
SCHEDULE 2
→
SCHEDULE 5
→
SCHEDULE 6 each time the start signal (1ST and 2ND) is input.
The CHAINING setting has a priority to the SUCCESSIVE setting.
n. FORGE DELAY
The forge force function can be used.
The forge valve can be used at the given timing (the head force can be changed) except the valve
selected in
VALVE #
.
Set the timing to output the forge force.
Operation differs according to the VALVE MODE setting on the MODE SELECT screen.
When VALVE MODE is 1 VALVE
The forge valve operates from the end of SQD through the forge delay time elapses.
When VALVE MODE is 2 VALVE
The forge valve operates from the beginning of WE1 through the forge delay time elapses.
Valid only when FORGE MODE is set to ON.
o. FORGE MODE
The forge force function can be used.
The forge valve can be used at the given timing (the head force can be changed) except the valve
selected in
VALVE #
.
Set whether or not to use the forge force.